24 / 28 page ![]() 33892 MOTOROLA ANALOG INTEGRATED CIRCUIT DEVICE DATA 24 Loss of VDD If the external 5.0 V supply is not within specification, or even disconnected, all register content is reset. The outputs can still be driven by the direct inputs IN[0:3]. The 33892 uses the battery input to power the output MOSFET-related current sense circuitry and any other internal logic providing fail-safe device operation with no VDD supplied. In this state, the watchdog, overvoltage, overtemperature, and overcurrent circuitry are fully operational with default values. Fault Mode The 33892 indicates the faults below as they occur by driving the FS terminal to [0]: • Overtemperature fault • Overvoltage and Undervoltage fault • Open load fault • Overcurrent fault (high and low) The FS terminal will automatically return to [1] when the fault condition is removed, except for overcurrent and in some cases undervoltage. Fault information is retained in the fault register and is available (and reset) via the SO terminal during the first valid SPI communication (refer to Table 10, page 22). Overtemperature Fault (Non-Latching) The 33892 incorporates overtemperature detection and shutdown circuitry in the output structure. Overtemperature detection is enabled when the output is in the ON state. For the output, an overtemperature fault (OTF) condition results in the faulted output turning OFF until the temperature falls below the TSD(HYS). This cycle will continue indefinitely until action is taken by the MCU to shut OFF the output, or until the offending load is removed. When experiencing this fault, the OTF fault bit will be set in the status register and cleared after either a valid SPI read or a power reset of the device. Overvoltage Fault (Non-Latching) The 33892 shuts down the output during an overvoltage fault (OVF) condition on the VPWR terminal. The output remains in the OFF state until the overvoltage condition is removed. When experiencing this fault, the OVF fault bit is set in the bit D1 and cleared after either a valid SPI read or a power reset of the device. The overvoltage protection can be disabled through SPI (bit OV_DIS). When disabled, the returned SO bit OD13 still reflects any overvoltage condition (overvoltage warning). Undervoltage Shutdown (Latching or Non-Latching) The output latches OFF at some battery voltage between 4.75 V and 5.75 V. As long as the VDD level stays within the normal specified range, the internal logic states within the device will be sustained. This ensures that when the battery level then returns above 5.75 V, the 33892 can be returned to the state that it was in prior to the low VPWR excursion. Once the output latches OFF, the outputs must be turned OFF and ON again to re-enable them. In the case IN[1:0]=0, this fault is non- latched. The undervoltage protection can be disabled through SPI (bit UV_DIS). When disabled, the returned SO bit OD14 still reflects any undervoltage condition (undervoltage warning). Open Load Fault (Non-Latching) The 33892 incorporates open load detection circuitry on the output. Output open load fault (OLF) is detected and reported as a fault condition when the output is disabled (OFF). The open load fault is detected and latched into the status register after the internal gate voltage is pulled low enough to turn OFF the output. The OLF fault bit is set in the status register. If the open load fault is removed, the status register will be cleared after reading the register. The open load protection can be disabled trough SPI (bit OL_DIS). Overcurrent Fault (Latching) The 33892 has eight programmable overcurrent low detection levels (IOCL) and two programmable overcurrent high detection levels (IOCH) for maximum device protection. The two selectable, simultaneously active overcurrent detection levels, defined by IOCH and IOCL, are illustrated in Figure 4, page 15. The eight different overcurrent low detection levels (IOCL0, IOCL1, IOCL2, IOCL3, IOCL4, IOCL5, IOCL6, and IOCL7) are illustrated in Figure 4. If the load current level ever reaches the selected overcurrent low detection level and the overcurrent condition exceeds the programmed overcurrent time period (tOCx), the device will latch the output OFF. If, at any time, the current reaches the selected IOCH level, then the device will immediately latch the fault and turn OFF the output, regardless of the selected tOCLx driver. For both cases, the device output will stay off indefinitely until the device is commanded OFF and then ON again. Reverse Battery The output survives the application of reverse voltage as low as -16 V. Under these conditions, the output’s gate is enhanced to keep the junction temperature less than 150°C. The ON resistance of the output is fairly similar to that in the Normal mode. No additional passive components are required. Ground Disconnect Protection In the event the 33892 ground is disconnected from load ground, the device protects itself and safely turns OFF the output regardless of the state of the output at the time of disconnection. Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |