| Electronic Components Datasheet Search |
|
MAX1153 Datasheet(PDF) 15 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1153 Datasheet(HTML) 15 Page - Maxim Integrated Products |
|
15 / 30 page ![]() Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor ______________________________________________________________________________________ 15 Manually Triggered Conversion (Command Code = 0000) Before beginning a manual conversion, ensure the scan mode bit in the setup register is zero, because a logic 1 disables manual conversions. The address bits in a Manually Triggered Conversion command select the input channel for conversion (see Table 3). When performing a differential conversion, use the even chan- nel address (AIN0, AIN2, AIN4, AIN6); the command is ignored if odd channel addresses (AIN1, AIN3, AIN5, AIN7) are used for a differential conversion. After issuing a Manually Triggered Conversion com- mand, bring CS high to begin the conversion. To obtain a correct conversion result, CS must remain high for a period longer than the reference power-up time (if in power-down mode) plus the conversion time for the selected channel-configured conversion type (voltage or temperature). The conversion’s result can then be read at DOUT by issuing a Read Current Data Register for Selected Channel command, addressing the con- verted channel. See Table 3 for channel addresses. Table 2. Command Description DATA BYTES AFTER COMMAND WORD COMMAND WORD BYTES TO DIN BYTES FROM DOUT COMMAND DESCRIPTION 0000#### 0 0 Manually Triggered Conversion 0001xxxx 0 3 Read Alarm Register 0010#### 0 2 Read Current Data Register for Selected Channel 0011#### 0 20 Read Current Data Register for All Channels 0100#### 0 5 Read Configuration Register for Selected Channel 0101xxxx 0 5 Read Global Configuration Registers 0110xxxx N/A N/A Reserved 0111xxxx 0 0 Reset 1000#### 0 0 Clear Alarm/Fault for Selected Channels 1001xxxx 0 0 Clear Alarm/Fault for All Channels 1010#### 2 0 Write Current Data Register for Selected Channel 1011xxxx 20 0 Write Current Data Registers for All Channels 1100#### 5 0 Write Configuration Registers for Selected Channel 1101xxxx 5 0 Write Global Configuration Registers 1110xxxx N/A N/A Reserved 1111xxxx N/A N/A Reserved #### = Channel address code, see Table 3. xxxx = These bits are ignored for this command. Table 3. Channel Address ADDRESS IN COMMAND INPUT 0000 Internal temperature 0001 VDD 0010 AIN0 0011 AIN1 0100 AIN2 0101 AIN3 0110 AIN4 0111 AIN5 1000 AIN6 1001 AIN7 1010 Reserved 1011 Reserved 1100 Reserved 1101 Reserved 1110 Reserved 1111 Reserved |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |