MAX1153 Datasheet(PDF) 16 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX1153 Datasheet(HTML) 16 Page - Maxim Integrated Products |
|
16 / 30 page ![]() Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor 16 ______________________________________________________________________________________ Read Alarm Register (Command Code 0001) The Read Alarm Register command, 0001, outputs the current status of the alarm register (see Table 11). The address bits in this command are ignored. The alarm register is 24 bits long and outputs in 3 bytes. Table 12 illustrates the encoding of the alarm register. After receiving an interrupt, read the alarm register to determine the source of the interrupt (see the Alarm Register section). Read Current Data Register for Selected Channel (Command Code 0010) The Read Current Data Register for Selected Channel command, 0010, outputs the data in the current data register of the selected channel. The address bits fol- lowing this command select the input channel to be read (see Table 3). The current data register is a 10-bit register. It takes 2 bytes to read its value. See the Output Data Format and Current Data Registers sec- tions for more details. See Table 3 for channel address- es. Also, see Figure 7. Read Current Data Register for All Channels (Command Code 0011) The Read Current Data Registers for All Channels com- mand, 0011, outputs the data in the current data regis- ters of all 10 channels, starting with the internal temperature sensor, then the VDD monitor, followed by AIN0 to AIN7. The address bits following this command are ignored. It takes 20 bytes to read all of the 10 chan- nels’ current data registers. Read Configuration Register for Selected Channel (Command Code 0100) The Read Configuration Register for Selected Channel command, 0100, outputs the configuration data of the channel selected by the address bits (see Table 3). The first register that shifts out is the upper threshold register (2 bytes), followed by the lower threshold regis- ter (2 bytes), ending with the channel configuration reg- ister (1 byte), all MSB first. It takes 5 bytes to read all three registers. See the Channel Registers section for more details. SCLK DIN DOUT C3 C2 C1 C0 A2 A1 A0 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 A3 CS Figure 7. Serial Register Read Timing |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |