50 / 68 page ![]() S0500-01 AFE LNAx ACTx INPx INMx Input 4500Ω 3600Ω 1800Ω 900Ω 450Ω IN LNA R Z A 1 2 = n + f IN IN IN LNA R Z / /C / /R A 1 2 = n + f AFE5808 SLOS688C – SEPTEMBER 2010 – REVISED APRIL 2012 www.ti.com Under the no termination configuration, the input impedance of the AFE5808 is about 6K Ω (8K//20pF) at 1 MHz. Passive termination requires external termination resistor Rt, which contributes to additional thermal noise. The LNA supports active termination with programmable values, as shown in Figure 84 . Figure 84. Active Termination Implementation The AFE5808 has four pre-settings 50,100, 200 and 400 Ω which are configurable through the registers. Other termination values can be realized by setting the termination switches shown in the above figure. Register [52] is used to enable these switches. The input impedance of the LNA under the active termination configuration approximately follows: (6) Table 5 lists the LNA RINs under different LNA gains. System designers can achieve fine tuning for different probes. The equivalent input impedance is given by Equation 7 where RIN (8K) and CIN (20pF) are the input resistance and capacitance of the LNA. (7) Therefore, the ZIN is frequency dependent and it decreases as frequency increases shown in Figure 10. Since 2MHz to approximately 10MHz is the most commonly used frequency range in medical ultrasound, this rolling-off effect doesn’t impact system performance greatly. Active termination can be applied to both CW and TGC modes. Since each ultrasound system includes multiple transducers with different impedances, the flexibility of impedance configuration is a great plus. Figure 32, Figure 33, andFigure 34 shows the NF under different termination configurations. It indicates that no termination achieves the best noise figure; active termination adds less noise than passive termination. Thus termination topology should be carefully selected based on each use scenario in ultrasound. 50 Submit Documentation Feedback Copyright © 2010–2012, Texas Instruments Incorporated Product Folder Link(s): AFE5808 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |