17 / 34 page ![]() SC5014 7 Phase-Shift PWM Dimming The SC504 provides an option for phase-shifted LED PWM dimming. This option is available in both PWMI indirect control and I2C control. The phase-shift option is set by the PH_SHIFT bit in the Device Control Register (register address 0x0). This option delays the turn-on of the LED strings based on the number of the strings in operation (the number of the strings in operation is determined during the start-up). The delay time can be calculated by the following equation: frequency dimming PWM LED f operation in strings of number N , N f T PWM PWM phase = = = − 1 φ Phase-shift mode is disabled during the soft-start period. This allows the output to ramp up to the correct voltage in a controlled fashion. Phase-shifting reduces the peak input current, decreases EMI and improves the dimming linearity. The figures in the Typical Characteristics Section on page 6 show the improvement in dimming linearity with phase-shifted versus non-phase-shifted dimming. Backlight Fade-in and Fade-out Options The SC504 features an option for fade-in and fade-out brightness control, which allows a smooth transition from one brightness level to another. Registers associated with these fading functions are shown in this section. Fade Option (register address 0x09) — sets fade enable options, fade time, fade type. Fade Rate (register address 0x0A) — sets fade step size option. The fade option register allows the user to select fading, choose between linear or logarithmic fading, and to set the fading time. The default setting is fading enabled with logarithmic mode. The fading time is determined by the LED PWM dimming frequency. The fade setting is shown in Table 2. . 2. An example for calculating the fading time is shown in this section. Assuming LED PWM dimming frequency is 0kHz, then 0-bits are assigned for 024 duty cycle settings. Table 2 — Fade Setting Duty Cycle Zone Duty Cycle Range Step Increment Step Interval Total Steps within the Range 0 to 5 2 52 2 52 to 767 256 3 768 to 024 2 256 The time required to go from 0% (02/024) to 90% (922/024) duty cycle can be calculated using the follow- ing equation: T PWM = 00 µs (with 0kHz dimming frequency) Cycle in Zone # = (5 - Starting Duty Cycle) x [(Zone # Step Interval) / (Zone # Step Increment)] Cycle in Zone #2 = Total Steps in Zone #2 x [(Zone #2 Step Interval) / (Zone #2 Step Increment)] Cycle in Zone #3 = (End Duty Cycle - 768) x [(Zone #3 Step Interval) / (Zone #3 Step Increment)] In this case, the total cycle will be: Total cycle = 2 x (5-02) + x 256 + 0.5 x (922 - 768) = 5 Total Fading Time = Total Cycle x T PWM = 5 x 00 µs = 5.ms Time required to go from 0% (02/024) to 90% (922/024) duty cycle can be calculated using the follow- ing equation: ms 115.1 T 1151 Time Total ) ( ) ( Cycle Total Period) Dimming (PWM μs 100 T PWM PWM = × = = − × + + − × = = 1151 768 922 2 1 256 102 511 2 Applications Information (continued) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |