Back Button HT46R016 Datasheet HTML 44Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 45Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 46Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 47Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 48Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 49Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 50Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 51Page - Holtek Semiconductor Inc HT46R016 Datasheet HTML 52Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 48 / 91 page
background image
Rev. 1.00
48
���� 1�� �01�
Rev. 1.00
49
���� 1�� �01�
HT46R016/HT46R017
Enhanced A/D Type 8-Bit OTP MCU
I/O Interfacing
The Timer/Event Counter, when configured to run in the event counter or pulse width capture
mode, requires the use of an external timer pin for its operation. As this pin is a shared pin it must
be configured correctly to ensure that it is setup for use as a Timer/Event Counter input pin. This is
achieved by ensuring that the mode selects bits in the Timer/Event Counter control register, either
the event counter or pulse width capture mode. Additionally the corresponding Port Control Register
bit must be set high to ensure that the pin is setup as an input. Any pull-high resistor connected to
this pin will remain valid even if the pin is used as a Timer/Event Counter input.
Programming Considerations
When configured to run in the timer mode, the internal system clock is used as the timer clock
source and is therefore synchronised with the overall operation of the microcontroller. In this mode
when the appropriate timer register is full, the microcontroller will generate an internal interrupt
signal directing the program flow to the respective internal interrupt vector. For the pulse width
capture mode, the internal system clock is also used as the timer clock source but the timer will only
run when the correct logic condition appears on the external timer input pin. As this is an external
event and not synchronised with the internal timer clock, the microcontroller will only see this
external event when the next timer clock pulse arrives. As a result, there may be small differences
in measured values requiring programmers to take this into account during programming. The same
applies if the timer is configured to be in the event counting mode, which again is an external event
and not synchronised with the internal system or timer clock.
When the Timer/Event Counter is read, or if data is written to the preload register, the clock is
inhibited to avoiderrors, however as this may result in a counting error, this should be taken into
account by the programmer. Care must be taken to ensure that the timers are properly initialised
before using them for the first time. The associated timer enable bits in the interrupt control
register must be properly set otherwise the internal interrupt associated with the timer will remain
inactive. The edge select, timer mode and clock source control bits in timer control register must
also be correctly set to ensure the timer is properly configured for the required application. It is
also important to ensure that an initial value is first loaded into the timer registers before the timer
is switched on; this is because after power-on the initial values of the timer registers are unknown.
After the timer has been initialized the timer can be turned on and off by controlling the enable bit in
the timer control register.
When the Timer/Event Counter overflows, its corresponding interrupt request flag in the interrupt
control register will be set. If the Timer/Event Counter interrupt is enabled this will in turn generate
an interrupt signal. However irrespective of whether the interrupts are enabled or not, a Timer/Event
Counter overflow will also generate a wake-up signal if the device is in a Power-down condition.
This situation may occur if the Timer/Event Counter is in the Event Counting Mode and if the
external signal continues to change state. In such a case, the Timer/Event Counter will continue
to count these external events and if an overflow occurs the device will be woken up from its
Power-down condition. To prevent such a wake-up from occurring, the timer interrupt request flag
should first be set high before issuing the “HALT” instruction to enter the Power Down Mode.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com