| Electronic Components Datasheet Search |
|
AD7851AR Datasheet(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7851AR Datasheet(HTML) 19 Page - Analog Devices |
|
19 / 36 page ![]() –19– REV. A AD7851 POWER-UP TIMES Using An External Reference When the AD7851 are powered up, the parts are powered up from one of two conditions. First, when the power supplies are initially powered up and, secondly, when the parts are powered up from either a hardware or software power-down (see last section). When AVDD and DVDD are powered up, the AD7851 enters a mode whereby the CONVST signal initiates a timeout followed by a self-calibration. The total time taken for this time-out and calibration is approximately 35 ms—see Calibration on Power-Up in the calibration section of this data sheet. During power-up the functionality of the SLEEP pin is disabled, i.e., the part will not power down until the end of the calibration if SLEEP is tied logic low. The power-up calibration mode can be disabled if the user writes to the control register before a CONVST signal is applied. If the time out and self-calibration are disabled, then the user must take into account the time required by the AD7851 to power up before a self-calibration is carried out. This power-up time is the time taken for the AD7851 to power up when power is first applied (300 µs typ) or the time it takes the external reference to settle to the 14-bit level—whichever is the longer. The AD7851 powers up from a full hardware or software power-down in 5 µs typ. This limits the throughput which the part is capable of to 120 kSPS for the K Grade and 126 kSPS for the A Grade when powering down between conversions. Fig- ure 24 shows how power-down between conversions is imple- mented using the CONVST pin. The user first selects the power-down between conversions option by using the SLEEP pin and the power management bits, PMGT1 and PMGT0, in the control register. See last section. In this mode the AD7851 automatically enters a full power-down at the end of a conver- sion, i.e., when BUSY goes low. The falling edge of the next CONVST pulse causes the part to power up. Assuming the ex- ternal reference is left powered up, the AD7851 should be ready for normal operation 5 µs after this falling edge. The rising edge of CONVST initiates a conversion so the CONVST pulse should be at least 5 µs wide. The part automatically powers down on completion of the conversion. Where the software con- vert start is used, the part may be powered up in software before a conversion is initiated. 5µs 3.25µs tCONVERT POWER-UP TIME NORMAL OPERATION FULL POWER-DOWN POWER-UP TIME START CONVERSION ON RISING EDGE POWER-UP ON FALLING EDGE CONVST BUSY Figure 24. Using the CONVST Pin to Power Up the AD7851 for a Conversion Using The Internal (On-Chip) Reference As in the case of an external reference, the AD7851 can power up from one of two conditions, power-up after the supplies are connected or power-up from hardware/software power-down. When using the on-chip reference and powering up when AVDD and DVDD are first connected, it is recommended that the power-up calibration mode be disabled as explained above. When using the on-chip reference, the power-up time is effec- tively the time it takes to charge up the external capacitor on the REFIN/REFOUT pin. This time is given by the equation: tUP = 9 × R × C where R ≈ 150K and C = external capacitor. The recommended value of the external capacitor is 100 nF; this gives a power-up time of approximately 135 ms before a calibration is initiated and normal operation should commence. When CREF is fully charged, the power-up time from a hardware or software power-down reduces to 5 µs. This is because an internal switch opens to provide a high impedance discharge path for the reference capacitor during power-down—see Figure 25. An added advantage of the low charge leakage from the reference capacitor during power-down is that even though the reference is being powered down between conversions, the refer- ence capacitor holds the reference voltage to within 0.5 LSBs with throughput rates of 100 samples/second and over with a full power-down between conversions. A high input impedance op amp like the AD707 should be used to buffer this reference capacitor if it is being used externally. Note, if the AD7851 is left in its powered-down state for more than 100 ms, the charge on CREF will start to leak away and the power-up time will increase. If this long power-up time is a problem, the user can use a partial power-down for the last conversion so the reference remains powered up. AD7851 REFIN/REFOUT EXTERNAL CAPACITOR SWITCH OPENS DURING POWER-DOWN BUF ON-CHIP REFERENCE TO OTHER CIRCUITRY Figure 25. On-Chip Reference During Power-Down POWER VS. THROUGHPUT RATE The main advantage of a full power-down after a conversion is that it significantly reduces the power consumption of the part at lower throughput rates. When using this mode of operation, the AD7851 is only powered up for the duration of the conver- sion. If the power-up time of the AD7851 is taken to be 5 µs and it is assumed that the current during power up is 12 mA typ, then power consumption as a function of throughput can easily be calculated. The AD7851 has a conversion time of 3.25 µs with a 6 MHz external clock. This means the AD7851 consumes 12 mA typ for 8.25 µs in every conversion cycle if the parts are powered down at the end of a conversion. The graph, Figure 26, shows the power consumption of the AD7851 as a function of throughput. Table VII lists the power consump- tion for various throughput rates. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |