13 / 16 page ![]() AD7884/AD7885 REV. C –13– AD7885 to 8088 Interface The AD7885, with its byte (8 + 8) data format, is ideal for use with the 8088 microprocessor. Figure 20 is the interface dia- gram. Conversion is started by enabling CSA. At the end of conversion, data is read into the processor. The read instruc- tions are: MOV AX, C001 Read 8 MSBs of data MOV AX, C000 Read 8 LSBs of data 8088 AD7885 ADDRESS DECODE LOGIC A15 – A8 AD7 – AD0 MN/MX +5 V HBEN IO/M ALE A0 RD ADDRESS BUS CONVST CS RD DB7 – DB0 CSA CSB DATA BUS STB 8282 Figure 20. AD7885 to 8088 Interface AD7884 to ADSP-2101 Interface Figure 21 shows an intcrface between the AD7884 and the ADSP-2101. Conversion is initiated using a timer which allows very accurate control of the sampling instant. The AD7884 BUSY line provides an interrupt to the ADSP-2101 when con- version is completed. The RD pulse width of the processor can be programmed using the Data Memory Wait State Control Register. The result can then be read from the ADC using the following instruction: MR0 = DM (ADC) where MR0 is the ADSP-2101 MR0 register, and where ADC is the AD7884 address. ADDRESS DECODE LOGIC ADSP-2101 DMA13 – DMA0 DMD15 – DMD0 IRQn DMS RD EN TIMER AD7884 ADDRESS BUS DATA BUS CONVST CS RD DB15 – DB0 BUSY Figure 21. AD7884 to ADSP-2101 Interface Stand-Alone Operation If CS and RD are tied permanently low on the AD7884, then, when a conversion is completed, output data will be valid on the rising edge of BUSY. This makes the device very suitable for stand-alone operation. All that is required to run the device is an external CONVST pulse which can be supplied by a sample timer. Figure 22 shows the AD7884 set up in this mode with the BUSY signal providing the clock for the 74HC574 3-state latches. TIMER AD7884 CONVST CS RD DB15 – DB8 BUSY HBEN A0 74HC574 74HC574 CLK CLK DB7 – DB0 Figure 22. Stand-Alone Operation Digital Feedthrough from an Active Bus It is very important when using the AD7884/AD7885 in a microprocessor-based system to isolate the ADC data bus from the active processor bus while a conversion is being executed. This will yield the best noise performance from the ADC. Latches like the 74HC574 can be used to do this. If the device is connected directly to an active bus then the converter noise will typically increase by a factor of 30%. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |