  ADM9264 Datasheet HTML 1Page - Analog Devices ADM9264 Datasheet HTML 2Page - Analog Devices ADM9264 Datasheet HTML 3Page - Analog Devices ADM9264 Datasheet HTML 4Page - Analog Devices ADM9264 Datasheet HTML 5Page - Analog Devices ADM9264 Datasheet HTML 6Page - Analog Devices ADM9264 Datasheet HTML 7Page - Analog Devices ADM9264 Datasheet HTML 8Page - Analog Devices ADM9264 Datasheet HTML 9Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 12 page
background image
–2–
REV. 0
ADM9264–SPECIFICATIONS
Parameter
Min
Typ
Max
Units
Test Conditions/Comments
OPERATING TEMPERATURE RANGE
–40
85
°C
Industrial (A Version)
VCC SUPPLY VOLTAGE
2.5
6.0
V
VCC SUPPLY CURRENT
25
75
µA
Digital Inputs = VCC/GND
SU1 INPUT RESISTANCE
200
240
k
Ω
I IN ~ 50
µA when SU1 = 12 V
SU2 INPUT RESISTANCE
85
100
k
Ω
I IN ~ 50
µA when SU2 = 5 V
SU3 INPUT RESISTANCE
55
66
k
Ω
I IN ~ 50
µA when SU3 = 3.3 V
SU4 INPUT RESISTANCE
45
56
k
Ω
I IN ~ 50
µA when SU4 = 2.8 V
SU1 HIGH TRIP POINT
12.72
12.96
13.2
V
Measured with SU1 Rising
SU2 HIGH TRIP POINT
5.35
5.45
5.55
V
Measured with SU2 Rising
SU3 HIGH TRIP POINT
3.53
3.60
3.66
V
Measured with SU3 Rising
SU4 HIGH TRIP POINT
2.94
3.00
3.05
V
Measured with SU4 Rising
SU1 LOW TRIP POINT
10.8
11.04
11.28
V
Measured with SU1 Falling
SU2 LOW TRIP POINT
4.45
4.55
4.65
V
Measured with SU2 Falling
SU3 LOW TRIP POINT
2.94
3.00
3.07
V
Measured with SU3 Falling
SU4 LOW TRIP POINT
2.55
2.60
2.66
V
Measured with SU4 Falling
SU1 HYSTERESIS
320
mV
Measured at SU1
SU2 HYSTERESIS
130
mV
Measured at SU2
SU3 HYSTERESIS
90
mV
Measured at SU3
SU4 HYSTERESIS
80
mV
Measured at SU4
GLITCH IMMUNITY
10
µs
100 mV Glitch on VCC or SU1-4
PROPAGATION DELAY
10
µs
Delay from Supply Going Outside
Tolerance until Output Changes
DIGITAL INPUT LOW, VIL
0.8
V
4.0 V < VCC < 6 V
DIGITAL INPUT HIGH, VIH
2.4
V
4.0 V < VCC < 6 V
DIGITAL INPUT LOW, VIL
0.5
V
2.5 V < VCC < 4.0 V
DIGITAL INPUT HIGH, VIH
2.0
V
2.5 V < VCC < 4.0 V
DIGITAL INPUT CURRENT
–1
+1
µA
(ERRX,
ERRY, DIS)
OPEN DRAIN OUTPUT LOW
0.4
V
10 k
Ω External to Positive Supply V+
OPEN DRAIN OUTPUT HIGH
V+ –0.25
V
10 k
Ω External to Positive Supply V+
SUPPLY RANGE FOR V+
2.5
6.0
V
V+ Can Be Different from VCC
Specifications subject to change without notice.
(VCC = Full Operating Range, TA = TMIN to TMAX unless otherwise noted)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com