Electronic Components Datasheet Search
  English  ▼

X  

M39006 Datasheet(PDF) 2 Page - AVX Corporation

Part # M39006
Description  MIL-PRF-39006 Series Military Conventional Wet Tantalum
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  AVX [AVX Corporation]
Direct Link  http://www.avx.com
Logo AVX - AVX Corporation

M39006 Datasheet(HTML) 2 Page - AVX Corporation

  M39006 Datasheet HTML 1Page - AVX Corporation M39006 Datasheet HTML 2Page - AVX Corporation M39006 Datasheet HTML 3Page - AVX Corporation M39006 Datasheet HTML 4Page - AVX Corporation M39006 Datasheet HTML 5Page - AVX Corporation M39006 Datasheet HTML 6Page - AVX Corporation M39006 Datasheet HTML 7Page - AVX Corporation M39006 Datasheet HTML 8Page - AVX Corporation M39006 Datasheet HTML 9Page - AVX Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 10 page
background image
MARCH 2013
■ 63
M39006
Type / Military
Designator
HOW TO ORDER MILITARY M39006 PART NUMBER:
–0081
Dash
Number
–
*H = High Vibration
(When Specified)
/22
Specification
Sheet
Number
Not RoHS Compliant
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
Frequency of
Applied
120Hz
800Hz
1kHz
Ripple Current
Ambient Still Air
≤55
85
105
125
≤55
85
105
125
≤55
85
105
125
Temperature (ºC)
% of
100%
0.60
0.39
–
–
0.71
0.43
–
–
0.72
0.45
–
–
85ºC
90%
0.60
0.46
–
–
0.71
0.55
–
_
0.72
0.55
–
–
Rated
80%
0.60
0.52
0.35
–
0.71
0.62
0.42
–
0.72
0.62
0.42
–
Peak
70%
0.60
0.58
0.44
–
0.71
0.69
0.52
–
0.72
0.70
0.52
–
Voltage 66-2/3%
0.60
0.60
0.46
0.27
0.71
0.71
0.55
0.32
0.72
0.72
0.55
0.32
Frequency of
Applied
10kHz
40kHz
100kHz
Ripple Current
Ambient Still Air
≤55
85
105
125
≤55
85
105
125
≤55
85
105
125
Temperature (ºC)
% of
100%
0.88
0.55
–
–
1.00
0.63
–
–
1.10
0.69
–
–
85ºC
90%
0.88
0.67
–
–
1.00
0.77
–
_
1.10
0.85
–
–
Rated
80%
0.88
0.76
0.52
–
1.00
0.87
0.59
–
1.10
0.96
0.65
–
Peak
70%
0.88
0.85
0.64
–
1.00
0.97
0.73
–
1.10
1.07
0.80
–
Voltage 66-2/3%
0.88
0.88
0.68
0.40
1.00
1.00
0.77
0.45
1.10
1.10
0.85
0.50
1/ At 125ºC the rated voltage of the capacitors decreases to 66 2/3 of the 85ºC rated voltage.
2/ The peak of the applied ac ripple voltage plus the applied dc voltage must not exceed the dc voltage rating of the capacitors.
3/ The ripple current listed in the parametric tables represents a rating calculated by using a maximum internal temperature rise (
ΔT) at
50°C at 40 kHz at 85°C ambient temperature, with a maximum peak rated voltage of 66.67 percent of the 85°C peak voltage rating.
RIPPLE CURRENT MULTIPLIERS vs. Frequency, temperature and applied voltage1/ 2/ 3/
*High vibration qualified parts are currently under development. Please contact the factory for additional details and availability.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com