| Electronic Components Datasheet Search |
|
MPC8315CVRADDA Datasheet(PDF) 63 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8315CVRADDA Datasheet(HTML) 63 Page - Freescale Semiconductor, Inc |
|
63 / 106 page ![]() MPC8315E PowerQUICC II Pro Processor Hardware Specifications, Rev. 2 Freescale Semiconductor 63 PCI Express Maximum time to transition to a valid electrical idle after sending an electrical idle ordered set TTX-IDLE-SET-TO-IDLE After sending an Electrical Idle ordered set, the Transmitter must meet all Electrical Idle Specifications within this time. This is considered a debounce time for the Transmitter to meet Electrical Idle after transitioning from L0. —— 20 UI — Maximum time to transition to valid TX specifications after leaving an electrical idle condition TTX-IDLE-TO-DIFF-DATA Maximum time to meet all TX specifications when transitioning from Electrical Idle to sending differential data. This is considered a debounce time for the TX to meet all TX specifications after leaving Electrical Idle —— 20 UI — Differential return loss RLTX-DIFF Measured over 50 MHz to 1.25 GHz. 12 — — dB 4 Common mode return loss RLTX-CM Measured over 50 MHz to 1.25 GHz. 6 — — dB 4 DC differential TX impedance ZTX-DIFF-DC TX DC Differential mode Low Impedance 80 100 120 — Transmitter DC impedance ZTX-DC Required TX D+ as well as D- DC Impedance during all states 40 — — — Lane-to-Lane output skew LTX-SKEW Static skew between any two Transmitter Lanes within a single Link — — 500 + 2 UI ps — AC coupling capacitor CTX All Transmitters shall be AC coupled. The AC coupling is required either within the media or within the transmitting component itself. 75 — 200 nF 8 Crosslink random timeout Tcrosslink This random timeout helps resolve conflicts in crosslink configuration by eventually resulting in only one Downstream and one Upstream Port. 0— 1 ms 7 Note: 1. No test load is necessarily associated with this value. 2. Specified at the measurement point into a timing and voltage compliance test load as shown in Figure 52 and measured over any 250 consecutive TX UIs. (Also refer to the transmitter compliance eye diagram shown in Figure 50.) 3. A TTX-EYE = 0.70 UI provides for a total sum of deterministic and random jitter budget of TTX-JITTER-MAX = 0.30 UI for the transmitter collected over any 250 consecutive TX UIs. The TTX-EYE-MEDIAN-to-MAX-JITTER median is less than half of the total TX jitter budget collected over any 250 consecutive TX UIs. It should be noted that the median is not the same as the mean. The jitter median describes the point in time where the number of jitter points on either side is approximately equal as opposed to the averaged time value. 4. The transmitter input impedance shall result in a differential return loss greater than or equal to 12 dB and a common mode return loss greater than or equal to 6 dB over a frequency range of 50 MHz to 1.25 GHz. This input impedance requirement applies to all valid input levels. The reference impedance for return loss measurements is 50 to ground for both the D+ and D– line (that is, as measured by a vector network analyzer with 50- probes, see Figure 52). Note that the series capacitors, C TX, is optional for the return loss measurement. 5. Measured between 20%–80% at transmitter package pins into a test load as shown in Figure 52 for both VTX-D+ and VTX-D-. 6. See Section 4.3.1.8 of the PCI Express Base Specifications, Rev 1.0a. 7. See Section 4.2.6.3 of the PCI Express Base Specifications, Rev 1.0a. 8. MPC8315E SerDes transmitter does not have CTX built-in. An external AC Coupling capacitor is required Table 54. Differential Transmitter (TX) Output Specifications (continued) Parameter Symbol Comments Min Typical Max Unit Note |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |