17 / 24 page ![]() Lineage Power 17 Data Sheet March 27, 2008 18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W LC/LW010- and LC/LW015-Series Power Modules: Thermal Considerations The power module operates in a variety of thermal environments; however, sufficient cooling should be provided to help ensure reliable operation of the unit. Heat-dissipating components inside the unit are ther- mally coupled to the case. Heat is removed by conduc- tion, convection, and radiation to the surrounding environment. Proper cooling can be verified by mea- suring the case temperature. The case temperature (TC) should be measured at the position indicated in Figures 41 and 42. 8-1363(C).b Note: Dimensions are in millimeters and (inches). Pin locations are for reference only. Figure 41. LW010 and LC010 Case Temperature Measurement Location 8-1363(C).c Note: Dimensions are in millimeters and (inches). Pin locations are for reference only. Figure 42. LW015 and LC015 Case Temperature Measurement Location Note that the views in Figures 41 and 42 are of the sur- face of the modules. The temperatures at these loca- tions should not exceed the maximum case temperature indicated on the derating curve. The out- put power of the module should not exceed the rated power for the module as listed in the Ordering Informa- tion table. Heat Transfer Characteristics Increasing airflow over the module enhances the heat transfer via convection. Figures 43 through 45 show the maximum power that can be dissipated by the mod- ule without exceeding the maximum case temperature versus local ambient temperature (TA) for natural con- vection through 3.0 ms–1 (600 ft./min.). Systems in which these power modules are used typi- cally generate natural convection airflow rates of 0.25 ms–1 (50 ft./min.) due to other heat dissipating components in the system. Therefore, the natural con- vection condition represents airflow rates of approxi- mately 0.25 ms–1 (50 ft./min.). Use of Figure 43 is shown in the following example. Example What is the minimum airflow necessary for an LW010A operating at 48 V, an output current of 2.0 A, and a maximum ambient temperature of 91 °C? Solution: Given: VI = 48 V, IO = 2.0 A (IO, max), TA = 91 °C Determine PD (Figure 58): PD = 2.5 W Determine airflow (Figure 43): v = 2.0 ms–1 (400 ft./min.) 8-1375(C).a Figure 43. LW010/LC010 Forced Convection Power Derating; Either Orientation dc-dc POWER MODULE 15.2 (0.6) + - + - OUT IN LW010/LC010 10.2 (0.4) dc-dc POWER MODULE 5.1 (0.2) + - + - OUT IN LW015/LC015 5.1 (0.2) 50 60 70 80 90 100 110 40 45 55 65 75 85 95 105 0 3.5 1.5 1 0.5 2 2.5 3 MAX AMBIENT TEMPERATURE, TA (˚C) MAXIMUM CASE TEMPERATURE 2.0 ms-1 (400 ft./min.) 3.0 ms-1 (600 ft./min.) 1.0 ms-1 (200 ft./min.) NATURAL CONVECTION |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |