BCD.00285_AA_September-18-2013
3
www.power-one.com
DATA SHEET
6.
Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
7.
Derate power linearly to 80% from 90 Vac to 80 Vac input.
8.
Power supply shipped with J3 pin 1 and 2 shorted to enable main output
9.
Specifications subject to change without notice.
10. Air flow over long edge (either direction) required for air flow rating. See mechanical drawing below.
11. Warranty 2 years.
General Specifications
PARAMETER
DESCRIPTION/CONDITION
Hold Up Time
120 Vac
10 mSec
230 Vac
10 mSec
MTBF
>250 khrs
Bellcore TR-332
Switching Frequency
PFC converter 80 kHz typical
Resonant converter: Variable 35 to 250
kHz, 90 kHz typical
Isolation Voltage
Min 5900 Vdc
Input to Output
Weight
450 g (0.99 lbs)
Environmental
PARAMETER
DESCRIPTION/CONDITION
Operating Temperature
Operating
-20 to 70° C. See derating charts below.
Storage
-40 to +85° C.
Altitude
Operating 10,000 ft.
Non-operation 40,000 ft.
Conducted emissions:
EN55022, FCC part 15 Level B
Radiated Emissions
EN55022, FCC part 15 Level B
To be controlled in end system
Electromagnetic Susceptibility
EN61000-4 3
2, 3, 4, 5 level 3
Harmonic Current
EN61000-3-2, Class D
Signals
PARAMETER
DESCRIPTION/CONDITION
Power Good
TTL signal goes high after main output is within regulation, delay is 0.1 to 0.3 sec
Inhibit
To turn on power supply short J3 pin 1 to J3 pin 2 or J3 pin 7
Remote Sense
Compensates for 200 mV drop
Safety
PARAMETER
DESCRIPTION/CONDITION
EN / UL / CSA
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1, UL60950-
1-2011



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com