15 / 38 page ![]() www.austriamicrosystems.com/AS3647 1.5-4 14 - 37 AS3647/47B Datasheet, Confidential - D e ta i l e d D e s c r i p t i o n Short Circuit Protection After the startup of the DCDC converter, the voltage on LED_OUT1/2 is continuously monitored and compared against VLEDSHORT if the LED current is above 25mA 7(see Figure 19). If the voltage across the LED (VFLED = VOUT1/2- LED_OUT1/2) stays below VLEDSHORT, the DCDC is stopped (as a shorted LED is assumed), the current sinks are dis- abled and the bit fault_led_short (see page 27) is set. Figure 19. Short LED detection Overtemperature Protection The junction temperature of the AS3647/47B is continuously monitored. If the temperature exceeds TOVTEMP, the DCDC is stopped, the current sinks are disabled (instantaneous) and the bit fault_overtemp (see page 27) is set. The driver is automatically re-enabled 8 once the junction temperature drops below TOVTEMP-TOVTEMPHYST. TXMASK event occurred If during flash, TXMASK current reduction is enabled (see TXMASK on page 16, configured by ext_torch_on=01) and a TXMASK event happened (pin TXMASK/TORCH=1), the fault register bit fault_txmask (see page 27) is set. Flash Timeout If the flash is started a timeout timer is started in parallel. If the flash duration defined by the STROBE input (strobe_on = 1 and strobe_type = 1, see Figure 26 on page 19) exceeds tFLASHTIMEOUT (adjustable by register flash_timeout (see page 26)), the DCDC is stopped and the flash current sinks (on pin LED_OUT1/2) are disabled and fault_timeout is set. If the flash duration is defined by the timeout timer itself (strobe_on = 0, see Figure 24 on page 19), the register fault_timeout is set after the flash has been finished. Supply undervoltage Protection If the voltage on the pin VIN (=battery voltage) is or falls below VUVLO, the AS3647/47B is kept in shutdown state and all registers are set to their default state. Wakeup Circuit - Power off detection In flash, assist light and indicator mode (register mode_setting (page 26)=01, 10 or 11) and out_on (page 26)=1, if SCL is L for more than tTIMEOUT, shutdown mode is automatically entered. This feature automatically detects a power-off of the controlling circuit driving SCL and SDA (VDD_I/F goes to 0V e.g. due to a low power condition of the driving circuit) - the internal circuit is shown in Figure 20: 7. To avoid errors in short LED detection for LEDs with a high leakage current 8. In constant voltage mode (const_v_mode=1) the DCDC will not be automatically re-enabled. !"! ## ! !$ % & ! ' |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |