| Electronic Components Datasheet Search |
|
AS3676 Datasheet(PDF) 77 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3676 Datasheet(HTML) 77 Page - ams AG |
|
77 / 92 page ![]() www.austriamicrosystems.com/AS3676 1v1-4 76 - 91 AS3676 Datasheet - D e ta i l e d D e s c r i p t i o n 8.9.1 Reset control register 8.10 Temperature Supervision An integrated temperature sensor provides over-temperature protection for the AS3676. This sensor generates a flag if the device temperature reaches the overtemperature threshold of 140º. The threshold has a hysteresis to prevent oscillation effects. If the device temperature exceeds the T140 threshold all current sources, the charge pump and the dcdc converter is disabled and the ov_temp flag is set. After decreasing the temperature by THYST operation is resumed. The ov_temp flag can only be reset by first writing a 1 and then a 0 to the register bit rst_ov_temp. Bit ov_temp_on = 1 activates temperature supervision (Table 118). It is recommend to leave this bit set (default state). VPOR_PERI Reset Level for pins CLK, DATA Monitor voltage on pins CLK, DATA 0.29 1.0 1.38 V tPOR_DEB Reset debounce time for pins CLK, DATA 80 100 120 ms tstart Interface Startup Time 4 6 8 ms 1. Guaranteed by design - min./max. limits not production tested Table 116. Reset and Overtemp control Register Addr: 29h Reset and Overtemp control This register reads and resets the overtemperature flag. Bit Bit Name Default Access Description 4 shutdwn_enab 0R/W Enable Shutdown mode and serial interface reset. 0 Serial Interface reset disabled. Device does not enter Shutdown mode 1 Serial Interface reset enabled, device enters shutdown when SCL and SDA remain low for tPOR_DEB Table 117. Overtemperature Detection Symbol Parameter Condition Min Typ Max Unit T140 ov_temp Rising Threshold 140 ºC THYST ov_temp Hysteresis 5 ºC Table 118. Reset and Overtemp control Register Addr: 29h Reset and Overtemp control This register reads and resets the overtemperature flag. Bit Bit Name Default Access Description 0 ov_temp_on 1W Activates/deactivates device temperature supervision. Default: Off - all other bits are only valid if this bit is set to 1 0 Temperature supervision is disabled. No reset will be generated if the device temperature exceeds 140ºC 1 Temperature supervision is enabled Table 115. Power On Reset Parameters Symbol Parameter Condition Min Typ Max Unit |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |