2 / 4 page ![]() Accessories Overview 3-phase voltage controllers which monitor : - Undervoltage, adjustable from -20 to -2 % of Un - Overvoltage, adjustable from 2 to 20 % of Un - Presence of the neutral (H3USN only) Measurements are taken between Phases for the H3US - M3US and between Phases and Neutral for the H3USN Faults are signalled via LEDs, distinguishing the origin of the fault (one LED for the upper threshold, one LED for the lower threshold). Voltage selector switch : Set the selector switch to the 3-phase network voltage Un. The position of this selector switch is only taken into account when the unit is powered up. If the switch position changes while the unit is operating, all the LEDs flash but the product continues to work normally with the voltage selected on energisation prior to the change of position. The LEDs return to their normal state if the switch is reset to its initial position defined before the last energisation. Operating principle H3US The relay monitors its own supply voltage. It controls : - Undervoltage, adjustable from - 2 to - 20 % of Un (-2 to -12 % over the 3 x 220 V AC range due to the minimum voltage 194 V AC) - Overvoltage, adjustable from + 2 to +20 % (+2 to +10 % over the 3 x 480 V AC range due to the maximum voltage 528 V AC). Each threshold has its own time delay with independent setting between 0.3 and 30 s. In the event of a voltage fault, the corresponding relay (one undervoltage output/one overvoltage output) opens at the end of the time delay set by the user. In the event of phase failure, both relays open instantaneously, without waiting for the end of the time delay. The two relay LEDs go out. H3USN The relay monitors its own supply voltage. It controls : - Presence of the neutral, - Undervoltage, adjustable from -2 to -20 % of Un, - Overvoltage, adjustable from +2 to +20 %. Connecting capacity IEC/EN 60947-1 Rigid : 1 x 4 2 - 2 x 2.52 mm2 1 x 11 AWG - 2 x 14 AWG Flexible with ferrules : 1 x 2.5 2 - 2 x 1.52 mm2 1 x 14 AWG - 2 x 16 AWG Max. tightening torques IEC/EN 60947-1 0,6 →1 Nm / 5,3 →8,8 Lbf.Ft Operating temperature IEC/EN 60068-2 - 20 →+50 °C Storage temperature IEC/EN 60068-2 - 40 →+70 °C Humidity IEC/EN 60068-2-30 2 x 24 hr cycle 95 % RH max. without condensation 55 °C Vibrations according to IEC/EN60068-2-6 10 →150 Hz, A = 0.035 mm Shocks IEC/EN 60068-2-6 5 g Standards Standards IEC/EN 50178, IEC/EN 61000-6-2, IEC/EN 61000-6-3 Certifications CE, UL, CSA, GL Conformity with environmental directives RoHS, WEEE Supply Supply voltage Un 3 x 220 →3 x 480 V AC * Voltage supply tolerance -12 % / +10 % Operating range 194 →528 V AC Power consumption at Un 22 VA in 400 VAC, 50 Hz Inputs and measuring circuit Selection of phase-phase nominal voltage Un 220-380-400-415-440-480 V AC Selection of phase-neutral voltage - Timing Delay on pick-up ≤ 650 ms Output Electrical life (number of operations) 1 x 10 4 General characteristics Casing 35 mm Weight 130 g Comments Description Code Removable sealable cover for 35 mm casing 84800001 Principles Principles H3US - H3USN - Under/Overvoltage Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 26/02/2014 www.crouzet.com |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |