| Electronic Components Datasheet Search |
|
DS1720 Datasheet(PDF) 3 Page - Dallas Semiconductor |
|
|
|||||||||||||||||||||||||||||
DS1720 Datasheet(HTML) 3 Page - Dallas Semiconductor |
|
3 / 12 page ![]() DS1720 030598 3/12 TEMPERATURE MEASURING CIRCUITRY Figure 2 SLOPE ACCUMULATOR PRESET PRESET COUNTER COUNTER =0 =0 STOP INC COMPARE TEMPERATURE REGISTER LOW TEMPERATURE COEFFICIENT OSCILLATOR HIGH TEMPERATURE COEFFICIENT OSCILLATOR SET/CLEAR LSB This calculation is done inside the DS1720 to provide 0.5 °C resolution. The temperature reading is provided in a 9–bit, two’s complement reading by issuing a READ TEMPERATURE command. Table 1 describes the exact relationship of output data to measured tempera- ture. The data is transmitted serially through the 3–wire serial interface, LSB first. The DS1720 can measure temperature over the range of –55 °C to +125°C in 0.5°C increments. For Fahrenheit usage, a lookup table or con- version factor must be used. TEMPERATURE/DATA RELATIONSHIPS Table 1 TEMP DIGITAL OUTPUT (Binary) DIGITAL OUTPUT (Hex) +85 °C 0 10101010 00AA +25 °C 0 00110010 0032h +1/2°C 0 00000001 0001h +0 °C 0 00000000 0000h –1/2°C 1 11111111 01FFh –25 °C 1 11001110 01CEh Since data is transmitted over the 3–wire bus LSB first, temperature data can be written to/read from the DS1720 as either a 9–bit word (taking RST low after the 9th (MSB) bit), or as two transfers of 8–bit words, with the most significant 7 bits being ignored or set to zero, as illustrated in Table 1. After the MSB, the DS1720 will output 0s. Note that temperature is represented in the DS1720 in terms of a 1/2°C LSB, yielding the following 9–bit format: X X X X X X X 1 1 1 0 01 11 0 MSB LSB T = –25 °C Higher resolutions may be obtained by reading the tem- perature, and truncating the 0.5 °C bit (the LSB) from the read value. This value is TEMP_READ. The value left in the counter may then be read by issuing a READ COUNTER command. This value is the count remain- ing (COUNT_REMAIN) after the gate period has ceased. By loading the value of the slope accumulator into the count register (using the READ SLOPE com- mand), this value may then be read, yielding the number of counts per degree C (COUNT_PER_C) at that tem- perature. The actual temperature may be then be calcu- lated by the user using the following: TEMPERATURE = TEMP_READ – 0.25 ) (COUNT_PER_C – COUNT_REMAIN) COUNT_PER_C |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |