4 / 12 page ![]() THIGH TLOW TCOM TL TH T ( °C) DS1720 030598 4/12 DETAILED PIN DESCRIPTION Table 2 PIN SYMBOL DESCRIPTION 1 DQ Data Input/Output pin for 3–wire communication port. 2 CLK/CONV Clock input pin for 3–wire communication port. When the DS1720 is used in a stand–alone application with no 3–wire port, this pin can be used as a convert pin. Temperature conversion will begin on the falling edge of CONV. 3 RST Reset input pin for 3–wire communication port. 4 GND Ground pin. 5 TCOM High/Low Combination Trigger. Goes high when temperature exceeds TH; will reset to low when temperature falls below TL. 6 TLOW Low Temperature Trigger. Goes high when temperature falls below TL. 7 THIGH High Temperature Trigger. Goes high when temperature exceeds TH. 8 VDD Supply Voltage. 2.7V – 5.5V input power pin. OPERATION–THERMOSTAT CONTROLS Three thermally triggered outputs, THIGH, TLOW, and TCOM, are provided to allow the DS1720 to be used as a thermostat, as shown in Figure 3. When the DS1720’s temperature meets or exceeds the value stored in the high temperature trip register, the output THIGH becomes active (high) and remains active until the DS1720’s measured temperature becomes less than the stored value in the high temperature register, TH. The THIGH output can be used to indicate that a high temperature tolerance boundary has been met or exceeded, or as part of a closed loop system can be used to activate a cooling system and to deactivate it when the system temperature returns to tolerance. The TLOW output functions similarly to the THIGH output. When the DS1720’s measured temperature equals or falls below the value stored in the low temperature regis- ter, the TLOW output becomes active. TLOW remains active until the DS1720’s temperature becomes greater than the value stored in the low temperature register, TL. The TLOW output can be used to indicate that a low temperature tolerance boundary has been met or exceeded, or as part of a closed loop system, can be used to activate a heating system and to deactivate it when the system temperature returns to tolerance. The TCOM output goes high when the measured tem- perature meets or exceeds TH, and will stay high until the temperature equals or falls below TL. In this way, any amount of hysteresis can be obtained. THERMOSTAT OUTPUT OPERATION Figure 3 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |