  PA75CC Datasheet HTML 1Page - List of Unclassifed Manufacturers PA75CC Datasheet HTML 2Page - List of Unclassifed Manufacturers PA75CC Datasheet HTML 3Page - List of Unclassifed Manufacturers PA75CC Datasheet HTML 4Page - List of Unclassifed Manufacturers PA75CC Datasheet HTML 5Page - List of Unclassifed Manufacturers  
Zoom Inzoom in Zoom Outzoom out
 4 / 5 page
background image
4
PA75U
PA75
GENERAL
Please readApplication Note 1“General Operating Consider-
ations” which covers stability, supplies, heatsinking, mounting,
SOA interpretation, and specification interpretation.Visit www.
apexanalog.com for design tools that help automate tasks such
as calculations for stability, internal power dissipation, heatsink
selection;Apex Microtechnology’s complete Application Notes
library; Technical Seminar Workbook; and Evaluation Kits.
STABILITY CONSIDERATIONS
All monolithic power
op amps use output
stage topologies that
present special stabil-
ity problems. This is
primarily due to non-
complementary (both
devices are NPN)
output stages with a
mismatch in gain and
phase response for
different polarities of
output current. It is dif-
ficult for the op amp manufacturer to optimize compensation
for all operating conditions. For applications with load current
exceeding 300ma, oscillation may appear.The oscillation may
occur only with the output voltage swing at the negative or
positive half cycle. Under most operating and load conditions
acceptable stability can be achieved by providing a series RC
snubber network connected from the output to ground. The
recommended component values of the network are,RSN =
10Ω and CSN = 0.01µF. Please refer to Application Note 1 for
further details.
SAFE OPERATING AREA (SOA)
The SOA curves combine the effect of all limits for this power
op amp. For a given application, the direction and magnitude
of the output current should be calculated or measured and
checked against the SOA curves. This is simple for resistive
loads but more complex for reactive and EMF generating loads.
THERMAL CONSIDERATIONS
The PA75CD and CX have a large exposed copper heat
tab to which the monolithic is directly attached. The PA75CD
and CX may require a thermal washer, which is electrically
insulating since the tab is directly tied to -VS. This can result
in a thermal impedance RCS of up to 1˚C/W or greater.
The PA75CC has a large exposed integrated copper heatslug
to which the monolithic is directly attached.The solder connec-
tion of the heatslug to a minimum of 1 square inch foil area of
the printed circuit board will result in thermal performance of
25°C/W junction to air rating of the PA75CC.Solder connection
to an area of 1 to 2 square inches of foil is required for minimal
power applications
Where the PA75CC is used in higher power applications,
it is necessary to use surface mount techniques of heatsink-
ing. Surface mount techniques include the use of a surface
mount fan in combination with a surface mount heatsink on
the backside of the FR4/ PC board with through hole thermal
vias.Other highly thermal conductive substrate board materials
are available for maximum heat sinking.
MOUNTING PRECAUTIONS
1. Always use a heat sink. Even unloaded the PA75 can dis-
sipate up to .4 watts.
2. Avoid bending the leads. Such action can lead to internal
damage.
3. Always fasten the tab of the CD and CX package to the
heat sink before the leads are soldered to fixed terminals.
4. Strain relief must be provided if there is any probability of
axial stress to the leads.
SOA
TWO AMPLIFIERS
LOADED
ONE AMPLIFIER
LOADED
100.0
10.0
0.1
1.0
10.0
SUPPLY TO OUTPUT DIFFERENTIAL VOLTAGE, V
S - VO (V)
DC, T
C = 85°C
1.0
DC, T
C = 25°C
0
5
10
15
20
25
30
35
0
125
100
75
50
25
CASE TEMPERATURE, T
C (°C)
TWO AMPLIFIERS
LOADED
ONE AMPLIFIER
LOADED
POWER DERATING
–
+
C
SN
0.01µF
R
SN
10Ω



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com