8 / 15 page ![]() PRECAUTIONS FOR PROPER USE DP2 799 All models Error message Cause Corrective action Overcurrent due to short- circuit. Pressure is being applied during zero-point adjust- ment. Applied pressure exceeds the upper limit of displayable pressure range. Applied pressure exceeds the lower limit of displayable pressure range. Applied pressure exceeds the lower limit of displayable pressure range. Applied pressure exceeds the upper limit of displayable pressure range. Switch off the power supply and check the load. Applied pressure at the pressure port should be brought to atmospheric pres- sure and zero-point adjust- ment should be done again. Applied pressure should be brought within the rated pressure range. Error messages • When an error occurs, take the following corrective action. • This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal pressure detection sensor. • The DP2 series is designed for use with non- corrosive gas. It cannot be used with liquid or cor- rosive gas. • The DP2 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 (Note) and the following condition must be met to conform to that standard. Conditions in use for CE conformity Condition • If setting is impossible even with pressing the MODE key, verify whether the key-protect function is enabled. Please note that pressing down on the MODE key for an extended moment will enable the key-protect function as soon as the key is released. • If using the window comparator mode, set the pressure value so that there is a difference of 3 digits, or more, between Set Value 1 (P-1) and Set Value 2 (P-2). No output will be possible with a 0 to 2 digit difference. Operation Wiring The analog voltage output does not incorporate a short- circuit protection circuit. Do not directly connect a power supply or a capacitive load. • Make sure that the power supply is off while wiring. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • The sensor should be connected less than 10 m 32.808 ft from the power supply. Note: The EN 50082-2 that previously applied to the products for conforming to EMC Directive was replaced by EN 61000-6-2 starting April 1st, 2002. Displays measured pressure, settings, error messages and key-protect status. Lights up when Comparative Output 1 is ON. Lights up when Comparative Output 2 is ON. • In the initial setting mode, pressing the key changes the settable digit. • In the Set Value 1, 2 modes, pressing the key changes the set value to the high pressure side in case of positive pressure type sensor and to the high vacuum side in case of vacuum pres- sure type sensor. • In the sensing mode, if the key is pressed continuously for 4 sec. or more, the display shows peak hold value. • In the initial setting mode, pressing the key changes the set conditions. • In the Set Value 1, 2 modes, pressing the key changes the set value to the low pressure side in case of positive pressure type sensor and to the low vacuum side in case of vacuum pres- sure type sensor. • In the sensing mode, if the key is pressed continuously for 4 sec. or more, the display shows bottom hold value. • Each press of the key changes the selected mode to sensing mode, Set Value 1 (P-1) set mode and Set Value 2 (P-2) set mode. • In the sensing mode, if the key is pressed continuously for about 3 sec., key-protect can be set / released. • In the sensing mode, if the mode selection key is pressed while pressing the increment key ( ), the initial setting mode is obtained. Functional description DP2-20 –101.3kPa OUT2 OUT1 MODE 0-ADJ 1 2 3 6 4 5 31/2 digit LED display (Red) Comparative Output 1 operation indicator (Orange) Comparative Output 2 operation indicator (Green) 4 5 6 1 2 3 Increment key ( ) Mode selection key () MODE Decrement key ( ) Description Function |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |