59 / 59 page ![]() 80C186EB80C188EB 80L186EB80L188EB ERRATA An 80C186EB80L186EB with a STEPID value of 0001H has the following known errata A device with a STEPID of 0001H can be visually identified by the presence of an ‘‘A’’ alpha character next to the FPO number The FPO number location is shown in Figures 4 5 and 6 1 A19ONCE is not latched by the rising edge of RESIN A19ONCE must remain active (LOW) at all times to remain in the ONCE Mode Removing A19ONCE after RESIN is high will return all out- put pins to a driving state however the 80C186EB will remain in a reset state 2 During interrupt acknowledge (INTA) bus cycles the bus controller will ignore the state of the READY pin if the previous bus cycle ignored the state of the READY pin This errata can only oc- cur if the Chip-Select Unit is being used All active chip-selects must be programmed to use READY (RDY bit must be programmed to a 1) if wait- states are required for INTA bus cycles 3 CLKOUT will transition off the rising edge of CLKIN rather than the falling edge of CLKIN This does not affect any bus timings other than TCD 4 RESIN has a hysterisis of only 130 mV It is rec- ommended that RESIN be driven by a Schmitt triggered device to avoid processor lockup during reset using an RC circuit 5 SINT1 will only go active for one clock period when a receive or transmit interrupt is pending (ie it does not remain active until the S1STS register is read) If SINT1 is to be connected to any of the processor interrupt lines (INT0 – INT4) then it must be latched by user logic An 80C186EB80L186EB with a STEPID value of 0001H or 0002H has the following known errata A device with a STEPID of 0002H can be visually iden- tified by noting the presence of a ‘‘B’’ ‘‘C’’ ‘‘D’’ or ‘‘E’’ alpha character next to the FPO number The FPO number location is shown in Figures 4 5 and 6 1 An internal condition with the interrupt controller can cause no acknowledge cycle on the INTA1 line in response to INT1 This errata only occurs when Interrupt 1 is configured in cascade mode and a higher priority interrupt exists This errata will not occur consistantly it is dependent on in- terrupt timing REVISION HISTORY This data sheet replaces the following data sheets 270803-004 80C186EB 270885-003 80C188EB 270921-003 80L186EB 270920-003 80L188EB 272311-001 SB80C188EBSB80L188EB 272312-001 SB80C186EBSB80L186EB 59 59 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |