| Electronic Components Datasheet Search |
|
87C196 Datasheet(PDF) 21 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
87C196 Datasheet(HTML) 21 Page - Intel Corporation |
|
21 / 21 page ![]() AUTOMOTIVE 87C196KC 87C196KC B-3 STEP ERRATA 1 NMI during PTS skips an address When an NMI interrupts a PTS routine the first byte of the in- struction following completion of the PTS cycle is lost This results in incorrect code execution Workaround NMI must be disabled using exter- nal hardware during any PTS activity 2 QBD port glitch There is a strong negative glitch on all QBD Port pins (P1x and P26 P27) syn- chronous with the first falling edge of CLKOUT This glitch lasts about 10 ns and only occurs one time following the initial application of VCC The time for the pin to return to VCC may be several microseconds depending on pin loading capaci- tance Workaround External systems and devic- es should be disabled from responding to this glitch until after the first CLKOUT falling edge has occurred 3 Divide error during HOLD or READY The result of a signed divide instruction may be off by one if executed while the device is held off the bus by HOLD or READY and the queue is empty Specif- ic timings of HOLD or READY going active or in- active must be met Workaround for HOLD dis- able HOLD during signed divide operations (using hardware or software) Workaround for READY problem will only occur if unlimited wait state mode is selected and 14 or more wait states are inserted 4 The HSI unit has two errata one dealing with res- olution and the other with first entries into the FIFO The HSI resolution is 9 states instead of 8 states Events on the same line may be lost if they occur faster than once every 9 state times There is a mismatch between the 9 state time HSI resolution and the 8 state time timer This causes one time value to be unused every 9 timer counts Events may receive a time-tag on one count later than expected because of this ‘‘skipped’’ time value If the first two events into an empty FIFO (not including the Holding Register) occur in the same internal phase both are recorded with one time- tag Otherwise if the second event occurs within 9 states after the first its time-tag is one count later than the first time tag If this is the ‘‘skipped’’ time value the second event’s time-tag is 2 counts later than the first’s If the FIFO and Holding Register are empty the first event will transfer into the Holding Register after 8 state times leaving the FIFO empty again If the second event occurs after this time it will act as a new first event into an empty FIFO DATASHEET REVISION HISTORY The following are the key differences between this datasheet and the -003 version 1 The ‘‘advanced information’’ status was dropped and replaced with production status (no label) 2 Trademarks were updated 21 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |