5 / 13 page ![]() 4-95 Functional DescriptIon The dual counter-timer consists of two programmable 16-bit down counters, separately addressable and controlled by two independent 8-bit control registers. The word in the con- trol register determines the mode and type of operation that the counter-timer performs. Writing to or reading from a counter or register is enabled by selective addressing during a write or read cycle. The data is placed on the data bus by the microprocessor during the write cycle or read from the counter during the read cycle. Data to and from the counters and to the control registers is in binary format. Each counter-timer consists of three parts. The first is the counter itself, a 16-bit down counter that is decremented on the trailing edge of the clock input. The second is the jam register that receives the data when the counter is written to. The word in the control register determines when the jam register value is placed into the counter. The third part is the holding register that places the counter value on the data bus when the counter is read. When the counter has decremented to zero, three events occur. The first involves the common interrupt output pin that, if enabled, becomes active low. The second is the setting of a bit in the interrupt status register. This register can be read to determine which counter-timer has timed out. The third event is the logic change of the complemented output pins. In addition to the clock input used to decrement the counter, a gate input is available to enable or initiate operation. The counter-timers are independent and can have different mode operations. Write Operation The counters and registers are separately addressable and are programmed via the data bus when the chip is selected with the TPB/WR pin active. Normal sequencing requires that the counter jam register be loaded first with the required value (most significant and least significant byte in any order), and then the control register be accessed and loaded with the control word. The trailing edge of the TPB/WR pulse will latch the control word into the control register. The trailing edge of the first clock to occur with gate valid will cause the counter to be jammed with its initial value. The counter will decrement on the trailing edge of succeeding clocks as long as the gate is valid, until it reaches zero. The output levels will then change, and if enabled, the interrupt output will become active and the appropriate timer bit will be set in the interrupt status register. The interrupt output and the interrupt status register can be cleared (to their inactive state) by addressing the control reg- ister with the TPB/WR line active For example, if counter A times out, control register A must be accessed to reset the interrupt output high and reset the timer A bit in the status reg- ister low. Timer B bit in the status register will be unaffected. Read Operation Each counter has a holding register that is continuously being updated by the counter and is accessed when the counter is addressed during read cycles. Counter reads are accomplished by halting the holding register and then read- ing it, or by reading the holding register directly. If the holding register is read directly, data will appear on the bus if the counters are addressed with the RD line active. However, if the clock decrements the counter between the two read operations (most and least significant byte), an inaccurate value will be read. To preclude this from happening, writing a “1” into bit 6 of the control register and then addressing and reading the counter will result in a stable reading. This oper- ation prevents the holding register from being updated by the counter and does not affect the counter’s operation. The interrupt status register is read by addressing either control register with the RD line active. A “1” in bit 7 indicates Timer A has timed out and a “1” in bit 6 indicates Timer B has timed out. Bits 0-5 are zeros. Control Register Bits 0, 1 and 2 Mode Selects - See Mode Timing Diagrams (Figures 1, 2, 3, 4, and 5). Note: When selecting a mode, the timer outputs TAO and TBO are set low, and TAO and TBO are set high. If bits 0, 1 and 2 are all zero’s when the control register is loaded, no mode is selected, and the counter-timer outputs are unaffected. Issuing mode 6 will cause an indeterminate condition of the counter, issuing mode 7 is equivalent to issuing mode 5. 7 6543210 JAM ENABLE 1 = ENABLE 0 = DISABLE HOLDING REGISTER CONTROL 1 = FREEZE HOLDING REGISTER 0 = UPDATE CONTINUOUSLY START/STOP CONTROL 1 = START COUNTER 0 = STOP COUNTER INTERRUPT ENABLE 1 = ENABLE 0 = DISABLE GATE LEVEL SELECT 1 = POSITIVE (HIGH) 0 = NEGATIVE (LOW) MODE SELECT 001 = MODE 1 010 = MODE 2 †011 = MODE 3 100 = MODE 4 101 = MODE 5 †PLUS BIT 7 = 0 BIT 7 BIT 2 BIT 1 BIT 0 Mode 1 - Timeout - 0 0 1 Mode 2 - Timeout Strobe - 0 1 0 Mode 3 - Gate Controlled One Shot 0011 Mode 4 - Rate Generator - 1 0 0 Mode 5 - Variable-Duty Cycle - 1 0 1 No Mode selected. Counter outputs unaffected - 000 CDP1878C |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |