| Electronic Components Datasheet Search |
|
L6206 Datasheet(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6206 Datasheet(HTML) 21 Page - STMicroelectronics |
|
21 / 53 page ![]() 21/53 AN1762 APPLICATION NOTE Figure 21. Typical disable and delay time as a function of CEN, for several values of REN. 3.13 Adjusting the Over Current Detection trip point (L6206 ONLY) The L6206 allows the user to set the Over Current Detection threshold separately for the two full bridges con- necting two resistors (RCL) to pins PROGCLA and PROGCLB. The OCD threshold (ISOVER) follows the equa- tions: –ISOVER = 5.6A ±30% at -25 °C < Tj < 125 °C if RCL = 0 Ω (PROGCL connected to GND) –ISOVER = ±10% at -25 °C < Tj < 125 °C if 5K Ω < RCL < 40k Ω Figure 22 shows the OCD threshold versus RCL value in the range from 5kΩ to 40kΩ. 11 0 1 0 0 0. 1 1 10 C EN [ nF] 11 0 1 0 0 1 10 10 0 1 . 10 3 C EN [ nF] R EN = 220 k Ω R EN = 100 k Ω R EN = 47 k Ω R EN = 33 k Ω R EN = 10 k Ω 22100 R CL ---------------- |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|