Electronic Components Datasheet Search
  English  ▼

X  

MSK4366 Datasheet(PDF) 5 Page - M.S. Kennedy Corporation

Part # MSK4366
Description  38 Volt Maximum Operating Motor Supply Voltage
PDF  9 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MSK [M.S. Kennedy Corporation]
Direct Link  http://www.mskennedy.com
Logo MSK - M.S. Kennedy Corporation

MSK4366 Datasheet(HTML) 5 Page - M.S. Kennedy Corporation

  MSK4366_15 Datasheet HTML 1Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 2Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 3Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 4Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 5Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 6Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 7Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 8Page - M.S. Kennedy Corporation MSK4366_15 Datasheet HTML 9Page - M.S. Kennedy Corporation  
Zoom Inzoom in Zoom Outzoom out
 5 / 9 page
background image
Set Torque Integral Value – Commands controller to receive torque integral gain value.
Send Contents: Command Tag followed by 16 bits of data [3 words].
Command Tag: 0x18
Data: 0x0000 – 0x7FFF
Response Contents: Response Tag only [1 word].
Response Tag: 0x19
Description: Commands the controller to receive the torque integral gain factor for programming the compensation values for the torque
control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no integral gain at all, and that the
torque error loop will contain proportional gain only, if proportional gain has been programmed in. A value of 32767 would equal the maximum
possible gain. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up.
Default Data Value: 0x03E8
5
APPLICATION NOTES CONT'D
APPLICATION NOTES CONT'D
Set Current Command – Commands controller to set current direction and magnitude.
Send Contents: Command Tag followed by 16 bits of data [3 words].
Command Tag: 0x1A
Data: 0xFE51 - 0x01AF. 2’s compliment format.
Response Contents: Response Tag only [1 word].
Response Tag: 0x1B
Description: Commands the controller to receive the magnitude and direction of the torque. The command range will allow for a command of
+/- 431, which correspond to +/-14A RMS. Note that if at any point the measured current is higher than +/-14A, the bridge will be disabled
on a cycle by cycle basis.
Default Data Value: 0x0000
Get Measured Current – Get current measurement from controller.
Send Contents: Command Tag only [1 word].
Command Tag: 0x1C
Response Contents: Response Tag followed by 16 bits of data [3 words].
Response Tag: 0x1D
Data: 0xFE51 – 0x01AF. 2’s compliment format.
Description: Commands the controller to send the average of the last 200 measured current values, where the current is measured every
PWM duty cycle. This value should fall between +/-14A or +/-431. Note that if at any point the measured current is higher than +/-14A,
the bridge will be disabled on a cycle by cycle basis.
Default Data Value: N/A
Set Brake Mode – Commands controller to receive Brake command.
Send Contents: Command tag followed by 8 bits of data [2 words].
Command Tag: 0x20
Data: 0x01 – 0xFF
Response Content: Response Tag only [1 word].
Response Tag: 0x21
Description – Commands the controller to begin applying PWM brake signals to the output bridge and to reset the command and PID history
to 0. This is dissipative braking only, using the internal resistance of the motor windings and Back EMF to slow down the motor and apply
braking resistance to the shaft. Braking is achieved by turning on the bottom transistors of the bridge, regardless of shaft angle of the motor,
and using the shorting of the Back EMF voltage through the resistance of the motor windings essentially shorting all windings together.
However, this can be harsh if not applied in a controlled way. Control is achieved by implementing PWM modulation of the low side
transistors. Increasing the duty cycle will increase the amount of time each cycle that the windings are shorted together. An 8-bit word is
sent to the controller telling how long the ramp time is for increasing the duty cycle, with each bit being equal to about 7.8ms. A data value
of 1 would have a ramp time of 7.8ms and the full data value of 255 would be have a 2 second ramp time.
Default Data Value: N/A
8548-120 Rev. A 4/14



Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com