| Electronic Components Datasheet Search |
|
MSK4367 Datasheet(PDF) 5 Page - M.S. Kennedy Corporation |
|
|
|||||||||||||||||||||||||||||
MSK4367 Datasheet(HTML) 5 Page - M.S. Kennedy Corporation |
|
5 / 10 page ![]() 5 APPLICATION NOTES CONT'D Get Electrical Position – Requests motor rotor electrical position from controller. Send Contents: Command Tag only [1 word]. Command Tag: 0x36 Response Contents: Response Tag followed by 16 bits of data [3 words]. Response Tag: 0x37 Data: 0x0000 – 0x0168 Description: Will request motor rotor shaft electrical position from the controller in angular degrees, with zero (0) degrees being aligned with the Encoder Index Pulse. For a 4 pole motor, there will be two electrical rotations, 0 through 360 degrees, per one mechanical revolution of the rotor. Default Data Value: N/A Get Status – Requests status of controller. Send Contents: Command Tag only [1 word]. Command Tag: 0x10 Response Contents: Response Tag followed by 8 bits of data [2 words]. Response Tag: 0x11 Data: 0x01 – Running Mode 0x02 – Brake Mode 0x03 – Disable Mode Description: Will request status information from the controller. Status will indicate if control is in running mode, brake mode, or disable mode. Default Data Value: N/A Set Disable Mode – Commands controller to halt all PWM activity to the output bridge. Bridge is then inactive. Send Contents: Command Tag only [1 words]. Command Tag: 0x12 Response Contents: Response Tag only [1 word]. Response Tag: 0x13 Description: Commands the controller to disable the output bridge completely by shutting off all PWM modulation and all levels necessary to turn off all of the transistors. With the bridge now inactive, the motor can move freely. This does not reset command or PID history so motor will resume as last commanded when it is enabled. Default Data Value: Bridge is disabled by default. Set Speed Proportional Value – Commands controller to receive speed proportional gain value. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x38 Data: 0x0000 – 0x7FFF Response Contents: Response Tag only [1 word]. Response Tag: 0x39 Description: Commands the controller to receive the proportional gain factor for programming the compensation values for the speed control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no proportional gain at all, and that the speed error will go directly to the duty cycle control. A value of 32767 would equal the maximum possible gain. The controller must be in speed control mode in order for this to take effect. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x1964 Set Enable Mode – Commands controller to enable PWM activity to the output bridge. Bridge is then active. Send Contents: Command Tag only [1 words]. Command Tag: 0x14 Response Contents: Response Tag only [1 word]. Response Tag: 0x15 Description: Commands the controller to enable the output bridge. This will only have an effect if it is in disable mode or brake mode. The motor will resume normal control and move as previously commanded. Default Data Value: Bridge is disabled by default. 8548-100 Rev. C 3/13 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |