6 / 10 page ![]() 6 APPLICATION NOTES CONT'D Set Speed Integral Value – Commands controller to receive speed integral gain value. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x3A Data: 0x0000 – 0x7FFF Response Contents: Response Tag only [1 word]. Response Tag: 0x3B Description: Commands the controller to receive the integral gain factor for programming the compensation values for the speed control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no integral gain at all, and that error loop will contain proportional gain only, if proportional gain has been programmed in. A value of 32767 would equal the maximum possible gain. The controller must be in speed control mode in order for this to take effect. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x028A Set Torque Proportional Value – Commands controller to receive torque proportional gain value. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x16 Data: 0x0000 – 0x7FFF Response Contents: Response Tag only [1 word]. Response Tag: 0x17 Description: Commands the controller to receive the torque proportional gain factor for programming the compensation values for the torque control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no proportional gain at all, and that the torque error will go directly to the duty cycle control. A value of 32767 would equal the maximum possible gain. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x004A Set Torque Integral Value – Commands controller to receive torque integral gain value. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x18 Data: 0x0000 – 0x7FFF Response Contents: Response Tag only [1 word]. Response Tag: 0x19 Description: Commands the controller to receive the torque integral gain factor for programming the compensation values for the torque control digital error loop. Valid values are 0-32767. An input gain of 0 (zero) means that there will be no integral gain at all, and that the torque error loop will contain proportional gain only, if proportional gain has been programmed in. A value of 32767 would equal the maximum possible gain. The value is stored in non- volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x004B Encoder Resolution – Commands controller to receive encoder count resolution. Send Contents: Command Tag followed by 16 bits of data [3 words]. Command Tag: 0x3C Data: 0x0000 – 0x0800 Response Contents: Response Tag only [1 word]. Response Tag: 0x3D Description: Commands the controller to receive the encoder count resolution of the motor. The count will be the number of pulses from the encoder, starting and ending with the Index Pulse. This will be the number of counts, usually, for one complete mechanical revolution of the motor. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x01f4 Set Motor Poles – Commands controller to receive the number of motor poles. Send Contents: Command Tag followed by 8 bits of data [2 words]. Command Tag: 0x40 Data: 0x00 – 0x10 Response Contents: Response Tag only [1 word]. Response Tag: 0x41 Description: Commands the controller to receive the number of electrical poles in the motor. The number of poles is the number of magnetic north – south poles built onto the rotor shaft. Each pole pair, one magnetic north – south pair, represents one electrical revolution of the control electronics, 360 degrees of electrical angle input to the motor. A four pole motor will take two electrical revolutions of drive angle to achieve one complete mechanical revolution of the motor shaft. The value is stored in non-volatile memory and does not have to be re-introduced every time the device is powered up. Default Data Value: 0x0C4 8548-100 Rev. C 3/13 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |