13 / 34 page ![]() DocID017063 Rev 5 13/34 AN3154 Bootloader command set 33 3.3 Get ID command The Get ID command is used to get the version of the chip ID (identification). When the bootloader receives the command, it transmits the product ID to the host. Figure 8. Get ID command: host side 1. GID = Get ID. 2. PID stands for product ID. Byte 1 is the MSB and byte 2, the LSB of the address. Refer to Section 3.1: Get command for more details about the PID of the device you are using. The host sends messages as follows: Command message: Std ID = 0x02, data length code (DLC) = ‘not important’. ACK Message contain: Std ID = 0x02, DLC = 1, data = 0x79 - ACK |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|