16 / 24 page ![]() 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface 16 ______________________________________________________________________________________ Figure 11a shows the serial-interface timing necessary to perform a conversion every 15 SCLK cycles in exter- nal clock mode. If CS is low and SCLK is continuous, guarantee a start bit by first clocking in 16 zeros. Most microcontrollers (µCs) require that data transfers occur in multiples of eight clock cycles; 16 clocks per conversion is typically the fastest that a µC can drive the MAX1202/MAX1203. Figure 11b shows the serial-interface timing necessary to perform a conver- sion every 16 SCLK cycles in external clock mode. __________ Applications Information Power-On Reset When power is first applied and if SHDN is not pulled low, internal power-on reset circuitry activates the MAX1202/MAX1203 in internal clock mode, ready to convert with SSTRB = high. After the power supplies are stabilized, the internal reset time is 100µs. No con- versions should be performed during this phase. SSTRB is high on power-up, and if CS is low, the first logical 1 on DIN is interpreted as a start bit. Until a con- version takes place, DOUT shifts out zeros. Reference-Buffer Compensation In addition to its shutdown function, SHDN also selects internal or external compensation. The compensation affects both power-up time and maximum conversion speed. Compensated or not, the minimum clock rate is 100kHz due to droop on the sample-and-hold. Float SHDN to select external compensation. The Typical Operating Circuit uses a 4.7µF capacitor at REF. A value of 4.7µF or greater ensures stability and allows converter operation at the 2MHz full clock speed. External compensation increases power-up time (see the section Choosing Power-Down Mode, and Table 5). Internal compensation requires no external capacitor at REF, and is selected by pulling SHDN high. Internal compensation allows for the shortest power-up times, but the external clock must be limited to 400kHz during the conversion. Power-Down Choosing Power-Down Mode You can save power by placing the converter in a low- current shutdown state between conversions. Select full power-down or fast power-down mode via bits 1 and 0 of the DIN control byte with SHDN high or floating (Tables 2 and 6). Pull SHDN low at any time to shut down the converter completely. SHDN overrides bits 1 and 0 of the control byte. Full power-down mode turns off all chip functions that draw quiescent current, reducing IDD and ISS typically to 2µA. For the MAX1202, fast power-down mode turns off all circuitry except the bandgap reference. With fast power-down mode, the supply current is 30µA. Power-up time can be shortened to 5µs in internal compensation mode. Since the MAX1203 does not have an internal reference, power-up times coming out of full or fast power-down are identical. IDD shutdown current can increase if any digital input (DIN, SCLK, CS) is held high in either power-down mode. The actual shutdown current depends on the state of the digital inputs, the voltage applied to the digi- tal inputs (VIH), the supply voltage (VDD), and the operat- ing temperature. Figure 12c shows the maximum IDD increase for each digital input held high in power-down mode for different operating conditions. This current is cumulative, so if all three digital inputs are held high, the additional shutdown current is three times the value shown in Figure 12c. In both software power-down modes, the serial interface remains operational, but the ADC does not convert. Table 5 shows how the choice of reference-buffer com- pensation and power-down mode affects both power-up delay and maximum sample rate. In external compensa- tion mode, power-up time is 20ms with a 4.7µF compen- sation capacitor (200ms with a 33µF capacitor) when the capacitor is initially fully discharged. From fast power-down, start-up time can be eliminated by using low-leakage capacitors that do not discharge more than 1/2LSB while shut down. In power-down, the capacitor has to supply the current into the reference (typically 1.5µA) and the transient currents at power-up. Figures 12a and 12b show the various power-down sequences in both external and internal clock modes. Software Power-Down Software power-down is activated using bits PD1 and PD0 of the control byte. As shown in Table 6, PD1 and PD0 also specify the clock mode. When software power-down is asserted, the ADC continues to operate in the last specified clock mode until the conversion is complete. The ADC then powers down into a low quies- cent-current state. In internal clock mode, the interface remains active and conversion results can be clocked out even though the MAX1202/MAX1203 have already entered software power-down. The first logical 1 on DIN is interpreted as a start bit and powers up the MAX1202/MAX1203. Following the start bit, the control byte also determines clock and power-down modes. For example, if the DIN word con- tains PD1 = 1, the chip remains powered up. If PD1 = 0, power-down resumes after one conversion. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |