Electronic Components Datasheet Search
  English  ▼

X  

MAX3056ASD Datasheet(PDF) 6 Page - Maxim Integrated Products

Part # MAX3056ASD
Description  짹80V Fault-Protected/Tolerant CAN Transceivers for In-Car Applications
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MAXIM [Maxim Integrated Products]
Direct Link  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

MAX3056ASD Datasheet(HTML) 6 Page - Maxim Integrated Products

Back Button MAX3056ASD Datasheet HTML 2Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 3Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 4Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 5Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 6Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 7Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 8Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 9Page - Maxim Integrated Products MAX3056ASD Datasheet HTML 10Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 18 page
background image
±80V Fault-Protected/Tolerant CAN
Transceivers for In-Car Applications
6
_______________________________________________________________________________________
AC ELECTRICAL CHARACTERISTICS (continued)
(VCC = 5V ±5%, VBATT = +5V to +42V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = 5V, VBATT = 14V, R1 = 100
Ω
(Figure 2), TA = +25°C.) (Notes 1, 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
MAX3054 (250kbps),
MAX3055 (125kbps)
0.36
1.14
1.90
Failures 3 and 8 Recovery Time
Normal and
low-power mode
MAX3056 (40kbps)
1.0
3.2
5.5
ms
MAX3054 (250kbps)
1.7
5.6
9.5
MAX3055 (125kbps)
7
23
38
Normal mode
MAX3056 (40kbps)
22
70
119
µs
MAX3054 (250kbps),
MAX3055 (125kbps)
0.35
1.1
1.85
Failures 4 and 7 Recovery Time
Low-power mode
MAX3056 (40kbps)
1.0
3.2
5.5
ms
MAX3054 (250kbps),
MAX3055 (125kbps)
150
525
900
Failure 6 Recovery Time
tREC
Normal mode
MAX3056 (40kbps)
390
1445
2500
µs
Minimum Hold Time of
Go-to-Sleep Command
tHMIN
550
µs
MAX3054 (250kbps),
MAX3055 (125kbps)
0.9
4.5
Disable Time of TXD Permanent
Dominant Timer
tDIS(TXD)
VTXD = 0
MAX3056 (40kbps)
2.34
12.50
ms
Pulse Count Difference for
Failures 1, 2, 5, 9 Detection (ERR
Becomes Low)
4
Pulse Count Difference for
Failures 1, 2, 5, 9 Recovery (ERR
Becomes High)
Count
34
5
Note 1: All currents into the device are positive; all currents out of the device are negative. All voltages are referenced to device
ground, unless otherwise noted.
Note 2: Failure modes 1 through 9 are explained in Table 1 and in the Detailed Description section.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com