8 / 26 page ![]() BATTERY MONITORING IC S-8229 Series Rev.1.0_01 Seiko Instruments Inc. 8 Standard Circuit OUT1 OUT2 OUT3 S-8229 Series ON / OFF VSS VDD ROUT1 ROUT2 ROUT3 R1 C1 Figure 8 Table 8 Constants for External Components Symbol Purpose Typ. Remark R1 *1 For power fluctuation 470 Ω Set the value as small as possible to prevent deterioration of the detection voltage. C1 For power fluctuation 0.1 μF Set R1 × C1 ≥ 40 × 10− 6. ROUTn *2 For output pin pull-up 100 k Ω Make sure the power dissipation of the S-8229 Series is not exceeded. *1. Set up R1 as 100 k Ω or less to prevent oscillation. *2. Set up each of ROUTn as 620 Ω or more so that the power dissipation is not exceeded. Caution The above connection diagram and constant will not guarantee successful operation. Perform thorough evaluation using the actual application to set the constant. Remark n = 1 to 3 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|