35 / 115 page ![]() PCM1861, PCM1863, PCM1865 www.ti.com SLAS831C – MARCH 2014 – REVISED AUGUST 2014 fSref = (PLLCLK_IN × K × R) / (N × P) : N is selected so that fSref × N = PLLCLK_IN × K × R / P is in the allowable range. Example: MCLK = 12MHz and fSref = 44.1kHz, (N=2048) Select P = 1, R = 1, K = 7.5264, which results in J = 7, D = 5264 Example: MCLK = 12MHz and fSref = 48.0kHz, (N=2048) Select P = 1, R = 1, K = 8.192, which results in J = 8, D = 1920 The PLL can be programmed via Page 0, Registers 20 thru 24. The PLL can be turned on via Page 0, Register 4, D(0). The variable P can be programmed via Page 0, Register 20, D(3:0). The variable R can be programmed via Page 0, Register 24, D(3:0). The variable J can be programmed via Page 0, Register 21, D(5:0). The variable D is 14-bits and is programmed into two registers. The MSB portion can be programmed via Page 0, Register 22, D(5:0), and the LSB portion is programmed via Page 0, Register 23, D(7:0). The variable D is set when the LSB portion is programmed. Values are programmed in the registers in Table 14. Table 14. PLL Coefficient Registers Register FUNCTION BITS PLL_EN PLL enable, Lock Page 0, Register 0x28 Status and PLL Reference PLL_P PLL P Page 0, Register 0x29 PLL_J PLL J Page 0, Register 0x2B Page 0, Register 0x2C (Least Significant Bits) PLL_Dx PLL D Page 0, Register 0x2D (Most Significant Bits) PLL_R PLL R Page 0, Register 0x2A 8.13.6 Clock Halt and Error The PCM186x has a clock error detection block inside that continues to monitor the ratio of BCK to LRCK. If a clock error is detected - such as an unexpected number of BCKs per LRCK, then the device will go into Standby mode, and an interrupt can be configured (software programmable devices) to inform the host. Should all clocks be stopped going into the device, then the device will shift into Sleep state and begin Energysense Signal Detect Mode. The status of the halt and error detector can be read from register: CLK_ERR_STAT (Page.0, 0x75). 8.14 ADCs 8.14.1 Main Audio ADCs The main ADCs in the PCM186x are 103dB, 40kHz bandwidth ADCs that are tightly coupled to dedicated PGAs and input multiplexers. Often in this document, references are made to ADC1L and ADC1R (or CH1_L and CH1_R), the main Left/Right ADCs present in both PCM1863 and PCM1865. References to ADC2L and ADC2R are the other pair of L/R ADCs present only in the PCM1865. 8.14.2 Secondary ADC - Energysense and Analog Control The PCM186x has a secondary ADC which is used for signal level detection or DC level change detection. Copyright © 2014, Texas Instruments Incorporated Submit Documentation Feedback 35 Product Folder Links: PCM1861 PCM1863 PCM1865 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |