Back Button PCM1865DBT Datasheet HTML 87Page - Texas Instruments PCM1865DBT Datasheet HTML 88Page - Texas Instruments PCM1865DBT Datasheet HTML 89Page - Texas Instruments PCM1865DBT Datasheet HTML 90Page - Texas Instruments PCM1865DBT Datasheet HTML 91Page - Texas Instruments PCM1865DBT Datasheet HTML 92Page - Texas Instruments PCM1865DBT Datasheet HTML 93Page - Texas Instruments PCM1865DBT Datasheet HTML 94Page - Texas Instruments PCM1865DBT Datasheet HTML 95Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 91 / 115 page
background image
PCM1861, PCM1863, PCM1865
www.ti.com
SLAS831C – MARCH 2014 – REVISED AUGUST 2014
RSV
Reserved
Reserved. Do not access.
TIME[4:0]
SIGDET_LOSS_TIME
If the signal drops below the threshold on the current audio input for this set amount of time, the device
generates an interrupt.
Default value: 00000
0: Prohibit
1: 1 minute (Default)
2: 2 minutes
3: 3 minutes
:
30: 30 minutes (Max)
Page 0 / Register 53 (Hex 0x35)
Dec
Hex
b7
b6
b5
b4
b3
b2
b1
b0
53
0x35
RSV
RSV
RSV
RSV
RSV
TIME2
TIME1
TIME0
Reset Value
0
0
0
0
0
0
0
0
RSV
Reserved
Reserved. Do not access.
TIME[2:0]
SIGDET_SCAN_TIME
Configures the scan time for each channel in the SLEEP state
Default value: 000
000: 160[msec] (Default)
001: 80[msec]
010: 40[msec]
011: 20[msec]
100: 10[msec]
Others: Invalid
Page 0 / Register 54 (Hex 0x36)
Dec
Hex
b7
b6
b5
b4
b3
b2
b1
b0
54
0x36
RSV
RSV
RSV
RSV
RSV
INT_INTVL2
INT_INTVL1
INT_INTVL0
Reset Value
0
0
0
0
0
0
0
1
RSV
Reserved
Reserved. Do not access.
INT_INTVL[2:0]
SIGDET_INT_INTVL
Interval time of the signal detector interrupt when there is signal detection. This time value is used for
Energysense wakeup from sleep interrupt and from Controlsense interrupts
Default value: 001
Interval time of the signal-resume interrupt
000: No repeat
001: 1 sec (Default)
010: 2 sec
011: 3 sec
100: 4 sec
Others: Invalid
Copyright © 2014, Texas Instruments Incorporated
Submit Documentation Feedback
91
Product Folder Links: PCM1861 PCM1863 PCM1865



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com