Electronic Components Datasheet Search
  English  ▼

X  

SP5730 Datasheet(PDF) 8 Page - Mitel Networks Corporation

Part # SP5730
Description  1.3GHz Low Phase Noise Frequency Synthesiser
PDF  14 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MITEL [Mitel Networks Corporation]
Direct Link  http://www.mitel.com
Logo MITEL - Mitel Networks Corporation

SP5730 Datasheet(HTML) 8 Page - Mitel Networks Corporation

Back Button SP5730 Datasheet HTML 4Page - Mitel Networks Corporation SP5730 Datasheet HTML 5Page - Mitel Networks Corporation SP5730 Datasheet HTML 6Page - Mitel Networks Corporation SP5730 Datasheet HTML 7Page - Mitel Networks Corporation SP5730 Datasheet HTML 8Page - Mitel Networks Corporation SP5730 Datasheet HTML 9Page - Mitel Networks Corporation SP5730 Datasheet HTML 10Page - Mitel Networks Corporation SP5730 Datasheet HTML 11Page - Mitel Networks Corporation SP5730 Datasheet HTML 12Page - Mitel Networks Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 14 page
background image
8
SP5730
Preliminary Information
MSB
LSB
Address
1
1
0
0
0
MA1
MA0
1
A
Byte 1
Status byte
POR
FL
0
0
0
0
0
0
A
Byte 2
Table 2 Read data format (MSB is transmitted first)
A
:
Acknowledge bit
MA1,MA0
:
Variable address bits (see Table 3)
2
14
- 2
0
:
Programmable division ratio control bits
R4-R0
:
Reference division ratio select (see Figure 3)
C1, C0
:
Charge pump current select (see Figure 6)
RE
:
REF/COMP output enable
RS
:
REF/COMP output select when RE=1 (see Figure 2)
T1-T0
:
Test mode control bits
P3-P0
:
P3 - P0 port output states
POR
:
Power on reset indicator
FL
:
Phase lock flag
MA1
MA0
Address input voltage level
0
0
0 - 0.1Vcc
0
1
Open circuit
1
0
0.4Vcc - 0.6Vcc #
1
1
0.9Vcc - Vcc
# Programmed by connecting a 30k
Ω ± 5% resistor between pin 10 and Vcc
Table 3 Address selection
RE.RS
T1
T0
Test mode description
0
0
0
Normal operation
1
0
0
Normal operation Port P0 = Fpd/2
X
0
1
Charge pump sink.* Status byte FL set to logic ‘0’
X
1
0
Charge pump source * Status byte FL set to logic ‘0’
X
1
1
Charge pump disabled * Status byte FL set to logic ‘1’
*clocks need to be present on crystal and RF inputs to enable charge pump test modes and to toggle
Status byte bit FL
X = Dont Care
Table 4 Test modes



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com