| Electronic Components Datasheet Search |
|
ADS1243IPWR Datasheet(PDF) 19 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ADS1243IPWR Datasheet(HTML) 19 Page - Texas Instruments |
|
19 / 25 page ![]() ADS1242, 1243 19 SBAS235B www.ti.com STOPC–Stop Continuous Description: Ends the continuous data output mode. Issue after DRDY goes LOW. Operands: None Bytes: 1 Encoding: 0000 1111 Data Transfer Sequence: RREG–Read from Registers Description: Output the data from up to 16 registers starting with the register address specified as part of the instruction. The number of registers read will be one plus the second byte count. If the count exceeds the remaining registers, the ad- dresses wrap back to the beginning. Operands: r, n Bytes: 2 Encoding: 0001 rrrr xxxx nnnn Data Transfer Sequence: Read Two Registers Starting from Register 01H (MUX) WREG–Write to Registers Description: Write to the registers starting with the register address specified as part of the instruction. The number of registers that will be written is one plus the value of the second byte. Operands: r, n Bytes: 2 Encoding: 0101 rrrr xxxx nnnn Data Transfer Sequence: Write Two Registers Starting from 04H (DIO) SELFCAL–Offset and Gain Self Calibration Description: Starts the process of self calibration. The Offset Calibration Register (OCR) and the Full-Scale Register (FSR) are updated with new values after this operation. Operands: None Bytes: 1 Encoding: 1111 0000 Data Transfer Sequence: SELFOCAL–Offset Self Calibration Description: Starts the process of self-calibration for offset. The Offset Calibration Register (OCR) is updated after this operation. Operands: None Bytes: 1 Encoding: 1111 0001 Data Transfer Sequence: SELFGCAL–Gain Self Calibration Description: Starts the process of self-calibration for gain. The Full-Scale Register (FSR) is updated with new values after this operation. Operands: None Bytes: 1 Encoding: 1111 0010 Data Transfer Sequence: D IN 0000 1111 xxx DRDY D IN 0001 0001 0000 0001 xxxx xxxx xxxx xxxx D OUT MUX ACR • • •(1) NOTE: (1) For wait time, refer to timing specification. 0101 0100 xxxx 0001 Data for DIO Data for DIR D IN D IN 1111 0000 D IN 1111 0001 D IN 1111 0010 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |