Back Button LMH0366 Datasheet HTML 11Page - Texas Instruments LMH0366 Datasheet HTML 12Page - Texas Instruments LMH0366 Datasheet HTML 13Page - Texas Instruments LMH0366 Datasheet HTML 14Page - Texas Instruments LMH0366 Datasheet HTML 15Page - Texas Instruments LMH0366 Datasheet HTML 16Page - Texas Instruments LMH0366 Datasheet HTML 17Page - Texas Instruments LMH0366 Datasheet HTML 18Page - Texas Instruments LMH0366 Datasheet HTML 19Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 38 page
background image
LMH0366
www.ti.com
SNAS585D – APRIL 2012 – REVISED APRIL 2013
The amount of time during which the eye opening monitor accumulates eye opening data can be set by the value
in register 0x29 (EOM_TIMER). In general, the greater this value, the longer the accumulation time.
Normal Eye Opening Monitor Mode
In normal eye opening monitor mode, the external controller has full control over the horizontal and vertical
coordinates, and must enable the measurement for each point. This provides the option to do a more coarse
measurement.
The procedure for normal EOM mode is as follows:
1. Enable the eye opening monitor by clearing register 0x14 bit 4 (EOM_PD).
2. Enable manual operation of the phase DAC and voltage DAC by setting register 0x22 bit 7 (EOM_OV).
3. Write the 6-bit phase DAC value to register 0x22 bits 5:0 (EOM_PDAC), and write the 6-bit voltage DAC
value to register 0x23 bits 5:0 (EOM_VDAC).
4. Enable the EOM counter by setting register 0x24 bit 0 (EOM_START), and poll for completion of the
measurement by reading this bit until it has cleared itself.
5. Read
register
0x25
(EOM_COUNT[15:8])
to
get
the
most
significant
byte
and
register
0x26
(EOM_COUNT[7:0]) to get the least significant byte of the hits counter, and store this value.
6. Repeat steps 3-5 for the remaining desired phase DAC and voltage DAC points. (In a typical application,
steps 2-4 will be repeated by sweeping through every voltage DAC setting at each phase DAC setting.)
Fast Eye Opening Monitor Mode
In fast eye opening monitor mode, the eye opening monitor sweeps through all 4096 phase and voltage DAC
settings autonomously. A new measurement at the next coordinate is automatically triggered when the current
16-bit count is ready and has been read. The full 64-by-64 point dimensions are used in this mode.
The procedure for fast EOM mode is as follows:
1. Enable the eye opening monitor by clearing register 0x14 bit 4 (EOM_PD).
2. Enable fast EOM mode by setting register 0x24 bit 7 (FAST_EOM).
3. Read register 0x26 (EOM_COUNT[7:0]) to clear the initial invalid data and start the EOM counter, and poll
for completion of the measurement by reading register 0x24 bit 0 (EOM_START) until it has cleared itself.
4. Read register 0x26 again to load the hits counter for read back and start the next measurement.
5. Poll for completion of the measurement by reading register 0x24 bit 0 (EOM_START) until it has cleared
itself.
6. Read
register
0x25
(EOM_COUNT[15:8])
to
get
the
most
significant
byte
and
register
0x26
(EOM_COUNT[7:0]) to get the least significant byte of the hits counter, and store this value. (Reading
register 0x26 will also automatically step to the next point in the EOM graph and initiate the measurement.)
7. Repeat steps 5-6 a total of 4096 times.
Measuring Horizontal and Vertical Eye Openings
The eye opening monitor can quickly detect and report the horizontal eye opening (HEO) and vertical eye
opening (VEO). The eye opening monitor first sweeps its variable-phase clock through one unit interval with the
comparison voltage set to the midpoint of the signal. This determines the midpoint of the horizontal eye opening.
The eye opening monitor then sets its variable-phase clock to the midpoint of the horizontal eye opening and
sweeps its comparison voltage. These two measurements determine the horizontal and vertical eye openings.
The procedure to measure the horizontal and vertical eye openings is as follows:
1. Enable the eye opening monitor by clearing register 0x14 bit 4 (EOM_PD).
2. Enable the measurement by setting register 0x24 bit 1 (GET_HEO_VEO), and wait for completion by reading
this bit until it has cleared itself.
3. Ensure
no
errors
have
occurred
by
verifying
that
register
0x24
bits
4:2
(VEO_MAX_ERR,
NO_OPENING_ERR, and NO_HITS_ERR) are all cleared.
4. Read the horizontal eye opening in register 0x2A (HEO) and the vertical eye opening in register 0x2B (VEO).
Copyright © 2012–2013, Texas Instruments Incorporated
Submit Documentation Feedback
15
Product Folder Links: LMH0366



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com