Back Button HT95168 Datasheet HTML 2Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 3Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 4Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 5Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 6Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 7Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 8Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 9Page - Holtek Semiconductor Inc HT95168 Datasheet HTML 10Page - Holtek Semiconductor Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 13 page
background image
Tone/Pulse Mode Setting
The HT95168 provides two kinds of dialing modes, tone mode and pulse mode. At On-hook state,
press the [*] key for 2 seconds to select the dialing mode.
· Tone Mode
Key Name
DTMF Output Frequency (Hz)
%Error
Specified
Actual
ROW3
697
698.8
+0.2%
ROW2
770
766.4
-0.5%
ROW1
852
847
-0.5%
ROW0
941
947.8
+0.6%
COL4
1209
1214.4
+0.4%
COL3
1336
1331
-0.3%
COL2
1477
1470
-0.4%
· Pulse Mode: Pulse rate: 10pps, M/B ratio: 40:60, Pulse to Tone duration: 3.6 seconds
Note
The initial dialing mode setting is tone mode.
Previous Edit and Immediately Dial Out
The HT95168 provides previous edit for dialing convenience and the maximum edit length is
32-digit, once off-hook or hand-free the edited number will be dialed out immediately. Besides,
pressing the [Call back/Redial] key or the [Add
¢0¢ Call back] key can also be dialed out directly.
Unauthorized-dialing Protection Setting
The meaning of [Unauthorized-dialing] is that the telephone line was illegally shunted by another
phone and making the line dial out.
· When the protection function is enabled, the HT95168 generates an interference signal to pro-
tect the line from being illegally used.
· At On-hook state, press the [#] key for 2 seconds, then turn on the LCD [Protection] icon to en-
able the protection function.
· Pressing again the [#] key for 2 seconds, turn off the icon to disable the function.
Note
The initial setting of this function is disabled.
To ensure that this function works normally for long distance conditions, fill-in or re-charge the bat-
tery.
HT95168
Rev. 1.10
6
March 22, 2004



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com