| Electronic Components Datasheet Search |
|
TPS65232 Datasheet(PDF) 12 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TPS65232 Datasheet(HTML) 12 Page - Texas Instruments |
|
12 / 32 page ![]() D q T = P JA · P = MAX T -T MAX ambient q JA ¾ = 120°C-55°C ¾ 25°C/W » 2.6 W P = MAX T - T MAX ambient q JA ¾ = 120°C - 75°C ¾ 18.1°C/W » 2.5 W 0 0.5 1 1.5 2 2.5 3 3.5 0 0.5 1 1.5 2 2.5 3 3.5 Curr ent from BUCK2 [A] @ 1.2V or less S afe Operating Area 0 0.5 1 1.5 2 2.5 3 3.5 0 0.5 1 1.5 2 2.5 3 3.5 Curr ent from BUCK2 [A] @ 1.8V Safe Operat ing Area 0 0.5 1 1.5 2 2.5 3 3.5 0 0.5 1 1.5 2 2.5 3 3.5 Curre nt from BUCK2 [A] @ 2.5V Sa fe Operating Area For any voltage / current comination inside the shaded area, the dissipated power inside the chip is below the allowable maximum. The examples assume T < 60°C, = 90% and < 44°C/W. ambient JA h q TPS65232 SLVSA42 – FEBRUARY 2010 www.ti.com 6-V REGULATOR The TPS65232 has a built-in 6-V regulator for powering internal circuitry. THERMAL MANAGEMENT AND SAFE OPERATING AREA Total power dissipation inside TPS65232 is limited not to exceed the maximum allowable junction temperature of 150°C. The maximum allowable power dissipation is a function of the thermal resistance of the package (qJA) and ambient temperature. qJA itself is highly dependent on board layout. The maximum allowable power inside the IC for operation at maximum ambient temperature without exceeding the temperature warning flag using the JEDEC High-K board is calculated as follows. (2) For TSSOP: (3) For QFN: (4) For different PCB layout arrangements the thermal resistance (qJA) will change as the following table shows. BOARD TYPE STACK-UP qJA 1.5-oz Cu, 60% Cu coverage top layer, 80% Cu coverage bottom 8" x 10" FR4 PCB, four layers layer, no airflow 29 0.5-oz 30% Cu coverage inner layers 1-oz Cu, 20% Cu coverage top layer, 90% Cu coverage bottom 8” x 10” FR4 PCB, two layers 44 layer, no airflow A minimum of two layers of 1-oz Cu with 20% Cu coverage on the top and 90% coverage on the bottom and the use of thermal vias to connect the thermal pad to the bottom layer is recommended. Note that the maximum allowable power inside the device will depend on the board layout. For recommendations on board layout for thermal management using TPS65232 consult your TI field application engineer. In the example shown above the maximum allowable power dissipation for the IC has been calculated. This figure includes all heat sources inside the device including the power dissipated in BUCK1, BUCK2, BUCK3 and all supporting circuitry. Power dissipated in BUCK1 and all supporting circuitry is approximately 0.4 W and almost independent of the application. Power dissipated in BUCK2 and BUCK3 depends on the output voltage, output current, and efficiency of the switching converters. The following examples of safe operating area assume 90% efficiency for BUCK2 and BUCK3, 3.3-V output from BUCK3 and 1.2-V, 1.8-V, and 2.5-V output from BUCK2, respectively. Figure 2. Examples of Thermal Safe Operating Area for V(BUCK3) = 3.3 V and V(BUCK1) = 1.2 V, 1.8 V and 2.5 V, Respectively 12 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TPS65232 Not Recommended for New Designs |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |