12 / 16 page ![]() 12 of 16 ELM320 ELM320DSC Elm Electronics – Circuits for the Hobbyist < http://www.elmelectronics.com/ > Monitoring the Bus Some vehicles use the OBD bus for information transfer during normal vehicle operation, passing a great deal of information over it. A lot can be learned if you have the good fortune to connect to one of these vehicles, and are able to decipher the contents of the messages. By the same token, you can do a lot of harm if you are careless, so be very careful. To see how your vehicle uses the OBD bus, you will have to enter one of the ELM320’s monitoring modes. The simplest is the “Monitor All” mode which is entered into by simply sending the command AT MA from your terminal program. Once received, the IC will continually display any information it sees on the OBD bus, regardless of transmitter or receiver addresses. Monitoring modes can only be stopped by sending something over the RS232 connection to the ELM320. It is not critical what you send - any single character will interrupt the processor, and return it to the command mode waiting for an input. Note that the character you send is discarded and has no effect on any subsequent commands. The IC will always finish a task in progress (printing a line, for example) before returning to wait for input, so always wait for the prompt character (‘>’) before continuing to issue other commands. If the headers are not currently displayed, simply typing ATMA shows only the contents of messages, not the transmitter and receiver addresses. To show who is sending to whom, you will need to first turn headers on (AT H1) before beginning to monitor (AT MA). Either way, you may end up with an overwhelming amount of information that you may want to filter, showing only specific messages. If, for example, you find that the engine controller’s address seems to be 10, you may want to restrict the data displayed to only messages from that ECU. To do so, you would monitor only for messages transmitted from address 10, by issuing AT MT 10 from your terminal program. Only messages with 10 in the third byte of the header will be displayed. Similarly, you may wish to only see messages which are being sent to address 3B. To monitor for these, send AT MR 3B and only messages with 3B as the second header byte will be shown. There are a few limitations to the current monitoring modes that you should be aware of. First, there is no internal buffering of OBD messages as data is being sent on the RS232 connection, so information may be missed while the IC is busy. If under computer control, you may want to consider the ‘packed data’ mode to reduce the chance of this. The second limitation is that the data being printed only extends up to the End Of Data symbol, and does not include any In-Frame Response bytes that may be present. However, for most users this will not be of consequence. Computer Control – Using Packed Data If a person is simply asking a vehicle for the current Diagnostic Trouble Codes, speed is normally not an issue, as data is displayed (essentially) as quickly as it can be read. If interfaced to a computer, however, speed may be important. The packed data mode is a convenient means to effectively triple the ELM320’s data transfer rate while maintaining the connection at 9600 baud. Once entered (with AT PD), all OBD messages will be returned as a single length byte followed by the actual data bytes. There are no space characters sent between bytes, no carriage returns or linefeeds – the data is retransmitted exactly as received from the vehicle (except for the change to 9600 baud). While no longer readable on a terminal, computers will understand the information just the same, and will gain speed through both reduced transfer and conversion times. The ELM320 does not function any differently when in this mode – if the headers are to be displayed, they are sent, if in monitoring mode, data is continually sent, etc. The only difference is in the format in which the OBD responses are returned to the controlling computer. Often there is no response from the vehicle for a particular request. When in the default (formatted data) mode, this is shown with ‘NO DATA’ being printed, but while in the packed data mode you will only receive a single length byte of value 0 (zero). While rare, errors may occasionally be detected in the vehicle’s data. Normally, a ‘<DATA ERROR’ would be printed for this, but in the Packed Data mode, the checksum (CRC) errors are identified by setting the most significant bit of the length byte. Because of this, one should always check the length byte for a value of 128 or greater before processing the remainder of the message. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |