| Electronic Components Datasheet Search |
|
ELM320P Datasheet(PDF) 13 Page - ELM Electronics |
|
|
|||||||||||||||||||||||||||||
ELM320P Datasheet(HTML) 13 Page - ELM Electronics |
|
13 / 16 page ![]() 13 of 16 ELM320 ELM320DSC Elm Electronics – Circuits for the Hobbyist < http://www.elmelectronics.com/ > Advanced Data Retrieval – Setting the Headers Prior to v2.0, the ELM320 used a fixed format for the message headers, allowing only for the retrieval of the mandated diagnostic codes, not allowing the user to change them. The IC is now fully programmable, however, allowing the headers to be changed and a great deal more information to be obtained, if your vehicle supports it. Note that only the OBDII diagnostic codes have been mandated, so there is no requirement for all vehicles to support these extra capabilities. The diagnostic trouble codes that most people are familiar with are described by SAE standard J1979 (ISO15031-5). This is really a specific instance of the many modes allowed by the J2178-4 standard, which allows for information transfer through what is known as ‘functional addressing’. For the OBDII mandated diagnostics, requests are actually made to the functional address 6A, with whatever processor is responsible for this function answering the request. Theoretically many different processors can respond to a single functional request, each contributing their insight as to the information requested. To retrieve some of this extra information, the function being addressed needs to be known. For example, consider that you have studied the J2178 standards and want to request that the processor responsible for Engine Coolant provide the current Fluid Temperature. You determine that Engine Coolant is functional address 48, you know that your address as a scan tool is normally F1, and that since the ELM320 only supports single IFR responses (type 1), you choose A1 as the initial priority/type byte. Combining the above then, it is desirable to set the three header bytes to A1 48 F1. This is done with the Set Header command, which would be issued at the prompt as follows: >AT SH A1 48 F1 The three header bytes assigned in this manner will stay in effect until changed with another AT SH command, a reset, etc. If the default Auto Receive mode has been selected, the receive address will automatically be set to 49 (the second byte plus one). This is consistent with the functional pairs assigned by J2178-4. If you decide that this is not appropriate for your case, you can always set the receive address to what you wish using the AT SR command. For example, if you wanted to obtain a response that is being sent to address E2 instead, you would use AT SR E2 to override the automatic receive mode. Any receive address selected stays in effect until changed by another AT SR, or reinstatement of the automatic mode. Having set the headers, all one needs to do is issue the secondary ID for fluid temperature (10) at the prompt. If the display of headers is set to on, the conversation would typically look like this: >10 81 49 10 10 2E 41 Ignoring the first three (header) bytes, and the final check digit, one can see that the response to ID 10 is the byte 2E. You may find that some requests, being of a low priority, are not answered immediately, possibly causing a NO DATA result. In these cases, you may want to adjust the timeout value, perhaps first trying the maximum (with AT ST FF). Using the physical addressing modes described by the J2190 standard involves an almost identical process. The main difference is that you must know the physical address of the device which you want to speak to. This is always the third byte of a message sent by any device, so can be determined by monitoring the headers (for the above response, the sender’s address is 10). Knowing that you wish to talk to address 10, that your physical address is F1, and that for type 1 IFR with physical addressing E4 may be appropriate for the first byte, you would change the header bytes using AT SH E4 10 F1. If Auto Receive is enabled, the receive address will automatically be set to F1, your physical address (the ELM320 knows to do this from the first byte). As before, this header will remain in effect for every message sent until changed to something else. One caution to note with physical addressing. There are modes which initiate the constant sending of data, and if the ELM320’s timeout is set longer than the duration between responses, the ELM320 may return messages forever. In these cases, just like in the monitoring modes, a single character will have to be sent to interrupt the process. Finally, please note that while we have provided some information on the SAE standards for the examples, Elm Electronics will only reply to requests for clarification on our product’s operation, and not on the standards. It is the customer’s responsibility to obtain their own information on the relevant standards, and on their vehicle. Requests to Elm Electronics for this information will go unanswered. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |