| Electronic Components Datasheet Search |
|
UTI760A Datasheet(PDF) 12 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
UTI760A Datasheet(HTML) 12 Page - List of Unclassifed Manufacturers |
|
12 / 48 page ![]() RTS-12 1.6 Terminal Address The Terminal Address of the RTS is programmed via five input pins: RTA(4:0) and RTPTY. Asserting MRST latches the RTS’s Terminal Address from pins RTA(4:0) and parity bit RTPTY. The address and parity cannot change until the next assertion of the MRST. The parity of the Terminal Address is odd; input pin RTPTY is set to a logic state to satisfy this requirement. A logic 1 on Status Register bit 12 indicates incorrect Terminal Address parity. An example follows: RTA(4:0) = 05 (hex) = 00101 RTPTY = 1 (hex) = 1 Sum of 1’s = 3 (odd), Status Register bit 12 = 0 RTA(4:0) = 04 (hex) = 00100 RTPTY = 0 (hex) = 0 Sum of 1’s = 1 (odd), Status Register bit 12 = 0 RTA(4:0) = 04 (hex) = 00100 RTPTY = 1 (hex) = 1 Sum of 1’s = 2 (even), Status Register bit 12 = 1 The RTS checks the Terminal Address and parity on Master Reset. The state of the DSCNCT signal indicates the mated status of the store. When all six Terminal Address pins (RTA(4:0), RTPTY) go to a logic one, the DSCNCT pin is asserted. To enable the disconnect function (DSCNCT pin) bit 11 of the Control Register is set to a logic one. With broadcast disabled, RTA (4:0) = 11111 operates as a normal RT address. 1.7 Internal Self-Test Setting bit 6 of the Control Register to a logic one enables the internal self-test. Disable Channels A and B at this time to prevent bus activity during self-test by setting bits 0 and 1 of the Control Register to a logic zero. Normal operation is inhibited when internal self-test is enabled. The self-test capability of the RTS is based on the fact that the MIL-STD- 1553B status word sync pulse is identical to the command word sync pulse. Thus, if the status word from the encoder is fed back to the decoder, the RTS will recognize the incoming status word as a command word and thus cause the RTS to transmit another status word. After the host invokes self-test, the RTS self-test logic forces a status word transmission even though the RTS has not received a valid command. The status word is sent to decoder A or B depending on the channel the host selected for self-test. The self-test is controlled by the host periodically changing the bit patterns in the status word being transmitted. Writing to the Control Register bits 2, 3, 4, 7, 8, and 10 changes the status word. Monitor the self-test by sampling either the Status Register or the external status pins (i.e., Command Strobe (COMSTR), Transmit/Receive (T/R)). For more detailed explanation of internal self-test, consult UTMC publication RTR/RTS Internal Self-Test Routine. 1.8 Power-up and Master Reset After power-up, reset initializes the part with its biphase ports enabled, latches the Terminal Address, selects Notice III subaddress decoding, and turns on the busy option. The device is ready to accept commands from the MIL-STD- 1553B bus. The busy flag is asserted while the host is loading the message pointers and messages. After this task is completed, the host removes the busy condition via a Control Register write to the RTS. On power-up if the terminal address parity (odd) is incorrect, the biphase inputs are disabled and the message error pin (MERR) is asserted. This condition can also be monitored via bit 12 of the Status Register. The MERR pin is negated on reception of first valid command. 1.9 Encoder and Decoder The RTS interfaces directly to a bus transmitter/ receiver via the RTS Manchester II encoder/decoder. The UT1760A RTS receives the command word from the MIL-STD- 1553B bus and processes it either by the primary or secondary decoder. Each decoder checks for the proper sync pulse and Manchester waveform, edge skew, correct number of bits, and parity. If the command is a receive command, the RTS processes each incoming data word for correct format and checks the control logic for correct word count and contiguous data. If an invalid message error is detected, the message error pin is asserted, the RTS ceases processing the remainder (if any) of the message, and it then suppresses status word transmission. Upon command validation recognition, the external status outputs are enabled. Reception of illegal commands does not suppress status word transmission. The RTS automatically compares the transmitted word (encoder word) to the reflected decoder word by way of the continuous loop-back feature. If the encoder word and reflected word do not match, the transmitter error pin (TXERR) is asserted. In addition to the loop-back compare test, a timer precludes a transmission greater than 760µs by the assertion of Fail-safe Timer (TIMERON). This timer is reset upon receipt of another command. (RT-to-RT transfer time-out = 57µs). 1.10 RT-RT Transfer Compare The RT-to-RT Terminal Address compare logic makes sure that the incoming status word’s Terminal Address matches the Terminal Address of the transmitting RT specified in the command word. An incorrect match results in setting the message error bit and suppressing transmission of the status word. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |