13 / 48 page ![]() RTS-13 1.11 Illegal Command Decoding The host has the option of asserting the ILLCOM pin to illegalize a received command word. On receipt of an illegal command, the RTS sets the Message Error bit in the status word, sets the message error output, and sets the message error latch in the Status Register. The following RTS outputs may be used to externally decode an illegal command, Mode Code or Subaddress indicator (MC/SA), Mode Code or Subaddress bus MCSA(4:0), Command Strobe (COMSTR), Broadcast (BRDCST), and Remote Terminal to Remote Terminal transfer (RTRT) (see figure 21 on page 34.) To illegalize a transmit command, the ILLCOM pin must be asserted within 3.3µs after VALMSG goes to a logic 1 if the RTS is to respond with the Message Error bit of the status word at a logic 1. If the illegal command is mode code 2, 4, 5, 6, 7, or 18, the ILLCOM pin must be asserted within 664ns after Command Strobe (COMSTR) transitions to logic 0. Asserting the ILLCOM pin within the 664ns inhibits the mode code function. For mode code illegalization, assert the ILLCOM pin until the VALMSG signal is asserted. For an illegal receive command, the ILLCOM pin must be asserted within 18.2µs after the COMSTR transitions to a logic 0 in order to suppress data words from being stored. In addition, the ILLCOM pin must be at a logic 1 throughout the reception of the message until VALMSG is asserted. This does not apply to illegal transmit commands since the status word is transmitted first. The above timing conditions also apply when the host externally decodes an illegal broadcast command. The host must remove the illegal command condition so that the next command is not falsely decoded as illegal. 2.0 MEMORY MAP EXAMPLE Figures 5 and 6 illustrate the UT1760A RTS buffering three receive command messages to Subaddress 4. The receive message pointer for Subaddress 4 is located at 03C4 (hex) in the 1K x 16 RAM. The 16-bit contents of location 03C4 (hex) point to the memory location where the first receive message is stored. The Address Field defined as bits 0 through 9 of address 03C4 (hex) contain address information. The Index Field defined as bits 10 through 15 of address 03C4 (hex) contain the message buffer index (i.e., number of messages buffered). Figure 5 demonstrates the updating of the message pointer as each message is received and stored. The memory storage of these three messages is shown in figure 6. After receiving the third message for Subaddress 4 (i.e., Index Field equals zero) the Address Field of the message pointer is not incremented. If the host does not update the receive message pointer for Subaddress 4 before the next receive command for Subaddress 4 is accepted, the third message will be overwritten. Figures 7 and 8 show an example of multiple message retrieval from Subaddress 16 upon reception of a MIL-STD- 1553B transmit command. The message pointer for transmit Subaddress 16 is located at 03F0 (hex) in the 1K x 16 RAM. The 16-bit contents of location 03F0 (hex) point to the memory location where the first message data words are stored. Figure 7 demonstrates the updating of the message pointer as each message is received and stored. The data memory for these three messages is shown in figure 8. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |