Back Button IMP16C554 Datasheet HTML 3Page - IMP, Inc IMP16C554 Datasheet HTML 4Page - IMP, Inc IMP16C554 Datasheet HTML 5Page - IMP, Inc IMP16C554 Datasheet HTML 6Page - IMP, Inc IMP16C554 Datasheet HTML 7Page - IMP, Inc IMP16C554 Datasheet HTML 8Page - IMP, Inc IMP16C554 Datasheet HTML 9Page - IMP, Inc IMP16C554 Datasheet HTML 10Page - IMP, Inc IMP16C554 Datasheet HTML 11Page - IMP, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 20 page
background image
transmitter are controlled separately either
one or both can in the polled mode operation
by utilizing the Line status Register.
A) LSR BIT-0 will be set as long as there is
one byte in the receive FIFO.
B) LSR BIT4-1 will specify which error(s) has
occurred.
C) LSR
BIT-5
will
indicate
when
the
transmit FIFO is empty.
D) LSR BIT-6 will indicate when both transmit
FIFO and transmit shift register are empty.
E) LSR BIT-6 will indicate when there are
any errors in the receive FIFO.
The MS16C554 requires to
have two step FIFO
enable operation in order to enable receive trigger
levels.
PROGRAMMABLE BAUD RATE
GENERATOR
The IMP16C554 contains a programmable Baud
Rate Generator that is capable of taking any
clock input from DC-24 MHz and dividing it by
any
divisor
from
1
to
216-1.The
output
frequency of the Baud out* is equal to 16X of
transmission baud rate (Baudout*=16 x Baud
Rate).
Customize
Baud
Rates
can
be
achieved by selecting proper divisor values for
MSB and LSB of baud rate generator.
INTERRUPT ENABLE REGISTER (IER)
The interrupt Enable Register (IER) masks the
incoming
interrupts
from
receiver
ready,
transmitter empty, line status and modem
status registers to the INT output pin.
IER BIR-0
0=disable the receiver ready interrupt.
1=enable the receiver ready interrupt.
IER BIR-1
0=disable the transmitter empty interrupt.
1=enable the transmitter empty interrupt.
IER BIR-2
0=disable the receiver line status interrupt.
1=enable the receiver line status interrupt.
IER BIR-3
0=disable the modem status register interrupt.
1=enable the modem status register interrupt.
IER BIR7-4
All these bits are set to logic zero.
INTERRUPT STATUS REGISTER (ISR)
The IMP16C554 provides four level prioritized
interrupt
conditions
to
minimize
software
overhead during data character transfers. The
interrupt Status Register (ISR) provides the
source of the interrupt in prioritized matter.
During the read cycle the IMP16C554 provides
the highest interrupt level to be serviced by
CPU. No other interrupts are acknowledged
until the particular interrupt is serviced. The
following sre the prioritized interrupt levels:
Priority level
P
D3
D2
C1
D0
Source
of
the
interrupt
1
2
2*
3
4
0
0
1
0
0
1
1
1
0
0
1
0
0
1
0
0
0
0
0
0
LSR (Receiver Line
Status Register)
RXRDY
(Received
Data Ready)
RXRDY
(Received
Data time out)
TXRDY
(Transmitter
Holding
Register
Empty)
MSR (Modem Status
Register)
*RECEIVE TIME-OUT:
This mode is enabled when the
UART is operating in FIFO mode. Receive
time out will not occur if the receive FIFO is
empty. The time out counter will be reset at
the center of each stop bit received or each
time out value is T (Time out length in bits)=4
X
P
(Programmed
word
length)+12.
To
convert time out value to a character value,
user has to divide this number to its complete
word length + parity (if used)+number of stop
bits and start bit.
Example-A:
if
user
programs
the
word
length=7,and no parity and one stop bit. Time
out
will
be:T=4x7(programmed
word
length)+12=40 bits Character time =40 / 9
(programmed
word
length=7)+(stop
bit=1)+(start bi=1)=4.4 characters.
Example-B:
if
user
programs
the
word
length=7,with parity and one stop bit, the time
out
will
be:
T=4x7
(programmed
word
length)+12=40 bits Character time =40 / 10
(programmed word length=7) + (parity=1) +
7
408-432-9100/www.impweb.com
© 2002 IMP, Inc.
IMP16C554
IMP16C554



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com