7 / 11 page ![]() 7 www.irf.com IRADK10 Cycle control description Figure 6. GUI control panel screen As stated above, the “GO CYCLE” command button of the GUI tool will bring you to the next form, wherein the drive cycle control may be adjusted, programmed, started and stopped. Observe 4 time intervals (t1, t2, t3, t4) and the frames where their duration may be adjusted by editing the number writ- ten in the appropriate fields. When adjusting these num- bers, make sure you enter an integer number of seconds not exceeding 30. For the time intervals t1 and t3, the assumed speed refer- ence is zero. Intervals t2 and t4 will have non-zero speeds. Their speeds W2 and W4, expressed in [Hz] may be ad- justed by editing the fields indicated by W2 [Hz] and W4 [Hz] labels. You must enter an integer number between 0 and 100. for both intervals, the direction of rotation is adjusted by writing into the CW/CCW fields. When a CW string is found in above fields (default), the CW direction of the motor shaft is commanded. Otherwise, for whatever string other than CW, the drive assumes a CCW direction. The cycle begins by pressing the “RUN” button. Whenever the user wants to stop the cycle, the STOP but- ton has to be pressed. The “STOP” button will decelerate the motor. During deceleration a “WAIT!!!” message will appear across the form, and the GUI will revert to the previ- ous frame once the speed reaches zero. While the cycle is running, the user may observe the DC-link current and the heat sink temperature. Drive Status Feedback The “DRIVE STATUS” display is the field where the GUI in- dicates what caused the drive to shut down protecting the power module. The micro controller will shut down the sys- tem if one of the following faults occurs: • Short Circuit: is shown when a short circuit is ap- plied from phase to phase at the output connec- tions. • Over Voltage: is shown when the DC bus voltage exceeds 400V. Note The bus voltage can climb to a shut down condition if the deceleration set- ting is set too high. • Under voltage: When the input AC voltage at the rectifier is insufficient to provide a bus voltage of 100VDC, the system shuts down and cannot start the motor. • I2T: This is the IGBT SOA protection. If the output power exceeds 400W for over 2 minutes, the power inverter will shut down preventing the power module from over-heating. • Heat sink over temperature: If the heat sink tem- perature rises more than “Heatsink temperature” set by the user, the system will shut down. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |