Back Button LM6182AMN Datasheet HTML 16Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 17Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 18Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 19Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 20Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 21Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 22Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 23Page - National Semiconductor (TI) LM6182AMN Datasheet HTML 24Page - National Semiconductor (TI)  
Zoom Inzoom in Zoom Outzoom out
 20 / 24 page
background image
Typical Applications (Continued)
The LM6182 crosstalk effect is minimized in applications that
cascade the amplifiers by preceding amplifier A with ampli-
fier B.
START-UP TIME
Using the circuit in
Figure 13, the LM6182 demonstrated a
start-up time of 50 ns.
OVERDRIVE RECOVERY
The LM6182 is an excellent choice for high speed applica-
tions needing fast overdrive recovery. Nanosecond recovery
times allow the LM6182 to protect subsequent stages from
excessive input saturation and possible damage.
When the output or input voltage range of a high speed am-
plifier is exceeded, the amplifier must recover from an over-
drive condition. The non-linear output voltage remains as
long as the overdrive condition persists. Linear operation re-
sumes after the overdrive condition is removed. Overdrive
recovery time is the delay before an amplifier returns to lin-
ear operation. The typical recovery times for exceeding open
loop, closed loop, and input commom-mode voltage ranges
are illustrated in
Figures 14, 15, 16.
The open-loop circuit of
Figure 14 generates an overdrive re-
sponse by allowing the ±0.5V input to exceed the linear in-
put range of the amplifier. Typical positive and negative over-
drive recovery times are 5 ns and 30 ns, respectively.
The large closed-loop gain configuration in
Figure 15 forces
the amplifier output into overdrive. The typical recovery time
to a linear output value is 15 ns.
DS011926-38
FIGURE 12. Crosstalk Rejection
DS011926-39
FIGURE 13. Start-Up Test Circuit
DS011926-41
DS011926-42
FIGURE 14. Open Loop Overdrive Recovery Times of
5 ns and 30 ns
DS011926-43
DS011926-44
FIGURE 15. 15 ns Closed Loop Output Overdrive
Recovery Time Generated by Saturating the Output
Stage of the LM6182
www.national.com
20



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com