2 / 4 page ![]() Double Pole Electronic Circuit Breaker ESS22-T www.e-t-a.de Double Pole Electronic Circuit Breaker ESS22-T 1646 2 4 Reset after overload or short circuit disconnection - remedy the external overload or short circuit failure - manual RESET on the breaker via ON/OFF switch - no reset with voltage interruptions (status memory) - no reset possible via external control input IN - external reset optionally possible via reset input RE Free-wheeling circuit external free-wheeling diode recommended with inductive load Load outputs must not be connected in parallel Status output SF ESS22-TA-0x1 Electrical data potential-free signal contact 1 break contact, terminal 11-12 (closed in OFF or failure condition) 1 make contact, terminal 13-14 (open in OFF or failure condition) max. DC 30 V / 0.5 A, min. 10 V / 10 mA Fault signal output fault conditions: - ON/OFF switch is in OFF position (manually) - after overload/short circuit disconnection - external control input (OFF) - low voltage - no operating voltage US Control input IN+/IN- ESS22-TA-01x / ESS22-TA-03x Electrical data control input (IN+/IN-) is physically isolated from load circuit (optocoupler) voltage max. + DC 32 V high > DC 12 V ≤ DC 32 V (switch on) low ≤ DC 5 V > 0 V (switch off) current consumption typically 3…9 mA (DC +12 V…32 V) Reset function ESS22-TA-03x A non-conducting load output (after an overload/short circuit disconnection) can be reset externally via the control input. In order to do that the control input has to be switched off for >100 ms Links manual ON/OFF switch on breaker is linked to the external control input IN+ by means of an AND function Reset input RE+ / RE- ESS22-TA-02x Electrical data reset input (RE+ / RE-) physically isolated from load circuit (optocoupler) voltage: max. + DC 32 V high > DC 12 V ≤ DC 32 V low ≤ DC 5 V > 0 V power consumption typically 3…9 mA (DC +12 V…32 V) min. pulse duration for RESET 100 ms Reset signal RE The electronically blocked load output (blocked after overload/short circuit disconnection) may be reset via an external reset pulse (+ DC 24 V). A common reset signal can be applied to several devices simultaneously. RESET - pulse/edge from low (min. 100 ms) to high (min. 100 ms) General data Fail-safe element failsafe element aligned to rated current (back-up fuse) Technical data (Tambient = 25 °C, operating voltage US = DC 24 V) Technical data (Tambient = 25 °C, operating voltage US = DC 24 V) Terminals Screw terminals M3 Max. cable cross section Rigid / flexible 0.14 – 2.5 mm2 (AWG 26-14) Wire stripping length 8 mm Tightening torque (EN 60934) 0.5 – 0.6 Nm Loop through option redundant LINE and LOAD terminals, max. cont. load for line entry 10 A Housing material moulded Mounting symmetrical rail to EN 50022-35x7.5 Ambient temperature 0...+50 °C (without condensation, see EN 60204-1) Storage temperature -20...+70 °C Humidity 96 hrs/95 % RH/40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721 Vibration 3 g, test to IEC 60068-2-6 test Fc Degree of protection housing: IP20 DIN 40050 terminals: IP20 DIN 40050 Standards, directives CE logo to EMC directive emitted interference: EN 61000-6-3 immunity to interference: EN 61000-6-2 surge voltages: EN 61000-4-5 Insulation co-ordination 0.5 kV/2 pollution degree 2 (IEC 60934) Insulation voltage DC 500 V between the physically isolated areas: load circuit in OFF condition, signal input and signal outputs Dielectric strength max. DC 32 V Reverse polarity protection integral Dimensions see following page (tolerances to DIN ISO 268 part 1 ± IT 13) Mass approx. 110 g Table 1: voltage drop, current limitation, max. load current current rating IN typically voltage drop UON at IN active current limitation (typically) max. load current at 100 % ON duty Tamb = 40 °C Tamb = 50 °C 0.5 A 80 mV 1.4 x IN 0.5 A 0.5 A 1 A 110 mV 1.4 x IN 1 A 1 A 2 A 140 mV 1.4 x IN 2 A 2 A 3 A 100 mV 1.4 x IN 3 A 3 A 4 A 130 mV 1.4 x IN 4 A 4 A 6 A 180 mV 1.4 x IN 6 A 6 A 8 A 130 mV 1.4 x IN 8 A 7 A 10 A 170 mV 1.4 x IN 10 A 9 Attention: when mounted side-by-side without convection the ESS22-T should not carry more than 80 % of its rated load with 100 % ON duty due to thermal effects. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |