| Electronic Components Datasheet Search |
|
ESS22-T Datasheet(PDF) 1 Page - ETAL Group |
|
|
|||||||||||||||||||||||||||||
ESS22-T Datasheet(HTML) 1 Page - ETAL Group |
|
1 / 4 page ![]() www.e-t-a.de Double Pole Electronic Circuit Breaker ESS22-T 1646 1 4 Operating data Operating voltage US DC 24 V (18...32 V) Current rating IN fixed current ratings: 0.5 A, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A Closed current I0 ON condition: typically 27 mA with signal output: typically 37 mA Status indication l multicolour LED: by means of GREEN: - unit is ON, load circuit switched on ORANGE: - in the event of overload or short circuit until disconnection RED: - after overload/short circuit disconnection - upon low voltage in ON condition - after switch-on till the end of the ON delay period OFF: - switched off by means of switch or control input - no operating voltage applied l potential-free signal contact l ON/OFF condition of switch Load circuit Load output Power-MOSFET and relay switching output with physical isolation, plus- and minus-switching Overload disconnection typically 1.1 x IN (1.05...1.35 x IN) Short-circuit current IK active current limitation typically 1.4 x IN (see table 1) Trip times see time/current characteristics typically 3 s at ILoad > 1.1 x IN typically 100 ms…3 s at ILoad > 1.4 x IN Temperature disconnection internal temperature monitoring with electronic disconnection Low voltage monitoring OFF at typically < 16.0 V ON at typically > 17.5 V automatic switch ON or OFF Starting delay tStart typically 0.5 sec after every switch-on, after reset and after applying US Disconnection of load circuit double pole, with physical isolation - manually on the breaker via ON/OFF switch (OFF) - after overload/short circuit disconnection - via external control input - at low voltage - no operating voltage applied Description Technical data (Tambient = 25 °C, operating voltage US = DC 24 V) ESS22-T The electronic circuit breaker type ESS22-T extends the E-T-A product range of electronic circuit protection for DC 24 V applications. It is a double pole version providing physical isolation. It meets the requirements of the machinery directive 2006/42/EC and the affiliated standard EN 60204-1 “Safety of Machinery, Electrical Equipment of Machines”, para 9.4.3.1. The combination of active electronic current limitation in the event of a short circuit and overload disconnection from 1.1 times rated current pro- vides double pole selective protection of DC 24 V load systems. DC 24 V power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. As well as an unidentified failure this also means stoppage of the whole system. Through selective disconnection the ESS22-T responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESS22-T limits the highest possible current to typically 1.4 times the selected rated current. Thus it is possible to switch on capacitive loads of up to 20,000 µF, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESS22-T can be selected in fixed values from 0.5 A...10 A. Failure and status indication are by a multicolour LED and integral signal contacts. Remote operation is possible by means of a physically isolated control input. The manual ON/OFF button allows separate actuation of individual load circuits. The ESS22-T, with a width of only 22.5 mm, can be snapped onto sym- metrical rails ensuring ease of installation and saving space in control cabinets. Upon detection of overload or short circuit in the load circuit, the MOSFET of the load output will be blocked to interrupt the current flow. In addition the load output will be physically isolated by a mechanical switching ele- ment. Upon failure remedy the load output of the ESS22-T is re-activated manually by operating the ON/OFF switch on the device or optionally by the physically isolated reset input and/or the control input. US patent number: US 6,490,141 B2 Features Approvals l Double pole electronic circuit breaker with physical isolation at load output l Double protection of “load+ path” through electronic protection and failsafe element l Double protection of “load- path” through electronic protection and failsafe element l Selective load protection, electronic trip curve l Active current limitation for safe connection of capacitive loads up to 20,000 µF, DC motors and on overload/short circuit l Fixed current ratings 0.5 A...10 A l Low voltage monitoring l Manual ON/OFF button l Physically isolated control input for ON/OFF optional l Physically isolated reset input RE optional l Clear status and failure indication through multicolour LED l Two signal contacts (break contact and make contact) l Width per unit 22.5 mm l Rail mounting Authority Standard Rated voltage Current ratings VDE EN 60934 DC 32 V 0.5 A…10 A UL UL 1077 C22.2 No 235 DC 30 V 0.5 A…10 A |
Similar Part No. - ESS22-T |
|
Similar Description - ESS22-T |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |