| Electronic Components Datasheet Search |
|
P1610000 Datasheet(PDF) 13 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
P1610000 Datasheet(HTML) 13 Page - Red Lion Controls. Inc |
|
13 / 28 page ![]() 13 2 I2 INPUT VALUE SCALING POINT 2 to 2 mA to 1 V For Key-in Method, enter the second coordinate Input Value by using the arrow keys. To allow the P16 to “learn” the signal, use the Applied Method. For Applied Method, press L. The ° annunciator is turned on to indicate the applied method. Adjust the applied signal level externally until the appropriate value appears under I2. Using either method, press A to store the value for I2 . (The controller can be toggled back to the Key-in Method by pressing L before A.) SETPOINT LOW LIMIT to The controller has a programmable low setpoint limit value to restrict the setting range of the setpoint. Set the limit so that the setpoint value cannot be set below the safe operating area of the process. I SETPOINT HIGH LIMIT to The controller has a programmable high setpoint limit value to restrict the setting range of the setpoint. Set the limit so that the setpoint value cannot be set above the safe operating area of the process. In USER INPUT FUNCTION (OPTIONAL) The controller performs the selected User Input function (User Input available only on models with alarms), when the User terminal 1 is connected (pulled low) to Common terminal 8. No Function: No function is performed. Program Lock: The Configuration Loop is locked, as long as activated (maintained action). Integral Action Lock: The integral action of the PID computation is disabled (frozen), as long as activated (maintained action). Auto/Manual Select: This function selects (maintained action) Automatic (open) or Manual Control (activated). Setpoint 1 or 2 Select: This function selects (maintained action) Setpoint 1(open) or Setpoint 2 (activated) as the active setpoint. Setpoint Ramp Disable: The setpoint ramping feature is disabled, as long as activated (maintained action). Any time the user input is activated with a ramp in process, ramping is aborted. Reset Alarms: Active alarms are reset, as long as activated (maintained action). Active alarms are reset until the alarm condition is cleared and triggered again (momentary action). SELECTION FUNCTION SELECTION FUNCTION No Function Setpoint 1 or 2 Select Program Lock Setpoint Ramp Disable I Integral Action Lock Reset Both Alarms nF Auto/Manual Select F1In F1 KEY FUNCTION The controller performs the selected F1 key function, when L is pressed while in the Display Loop. In any other loop or module location, pressing L will perform an escape to the Display Loop. No Function: No function is performed. Auto/Manual Select: This function toggles (momentary action) the controller between Automatic and Manual Control. Setpoint 1 or 2 Selection: This function toggles (momentary action) the controller between Setpoint 1 and Setpoint 2. Reset Alarms: This function can be used to reset one or both of the alarms when activated (momentary action). The alarm will remain reset until the alarm condition is cleared and triggered again. Reset Both Alarms Setpoint 1 or 2 Select Reset Alarm 2 2 Auto/Manual Select nF Reset Alarm 1 1 No Function FUNCTION SELECTION FUNCTION SELECTION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |