21 / 28 page ![]() 21 ON/OFF CONTROL The controller operates in On/Off Control when the Proportional Band is set to 0.0%. In this control mode, the process will constantly oscillate around the setpoint value. The On/Off Control Hysteresis (balanced around the setpoint) can be used to eliminate output chatter. Output O1 Control Action can be set to reverse for heating (output on when below the setpoint) or direct for cooling (output on when above the setpoint) applications. ON/OFF CONTROL - REVERSE OR DIRECT ACTING FIGURES Note: CHYS in the On/Off Control Figures refers to the On/Off Control Hysteresis () in parameter Module 2. For heat and cool systems, O1 Control Action is set to reverse (heat) and the Alarm 2 Action is set to cooling (O2). The Proportional Band is set to 0.0 and the Relative Gain in Cooling to 0.0. The Deadband in Cooling sets the amount of operational deadband or overlap between the outputs. The setpoint and the On/Off Control Hysteresis applies to both O1 and O2 outputs. The hysteresis is balanced in relationship to the setpoint and deadband value. Control mode explAnAtionS ON Output 2 (O2) : ON SP OFF INPUT HEAT/COOL DEADBAND (db2) = 0 SP + 1/2 CHYS SP - 1/2 CHYS OFF OFF Output 1 (O1) : ON CHYS SP SP + 1/2 (db-2) - 1/2 CHYS SP + 1/2 (db-2) + 1/2 CHYS SP - 1/2 (db-2) + 1/2 CHYS SP - 1/2 (db-2) - 1/2 CHYS HEAT/COOL DEADBAND (db-2) < 0 db-2 CHYS CHYS O2 ON O1 OFF O2 OFF O1 ON Output 1 (O1) : Output 2 (O2) : db-2 Output 1 (O1) : Output 2 (O2) : SP - 1/2 (db-2) + 1/2 CHYS SP - 1/2 (db-2) - 1/2 CHYS O1 OFF SP O1 ON O2 OFF O1 OFF O2 ON CHYS O2 OFF HEAT/COOL DEADBAND (db-2) > 0 SP + 1/2 (db-2) - 1/2 CHYS SP + 1/2 (db-2) + 1/2 CHYS CHYS O1 ON O2 ON INPUT INPUT SP + 1/2 (db-2) SP - 1/2 (db-2) SP + 1/2 (db-2) SP - 1/2 (db-2) ON/OFF CONTROL - HEAT/COOL OUTPUT FIGURES PID CONTROL In PID Control, the controller processes the input and then calculates a control output power value by use of a modified Proportional Band, Integral Time, and Derivative Time control algorithm. The system is controlled with the new output power value to keep the process at the setpoint. The Control Action for PID Control can be set to reverse for heating (output on when below the setpoint) or direct for cooling (output on when above the setpoint) applications. For heat and cool systems, the heat (O1) and cool (O2) outputs are both used. The PID parameters can be established by using Auto-Tune, or they can be Manually tuned to the process. SP TIME P & I P & I & D P only P & D INPUT TYPICAL PID RESPONSE CURVE OFF Output 1 (O1) : SP OFF INPUT DIRECT ACTING SP - 1/2 CHYS SP + 1/2 CHYS ON OFF Output 1 (O1) : SP OFF INPUT REVERSE ACTING SP - 1/2 CHYS SP + 1/2 CHYS ON |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |