14 / 22 page ![]() Detailed description STOD14 14/22 Doc ID 023562 Rev 1 under regulation about 10 ms after the Enable pin is asserted high. The short-circuit protection is designed to prevent overload, performing a dynamic current limitation on both output pins. At light load condition (up to 150 mA), the load can be connected during the startup phase. At medium/high load condition (above 150 mA), the proper sequence needs the startup phase to be entirely completed before connecting a load. 7.5 Fast discharge When the device goes into shutdown mode and LX1 and LX2 stop switching, the discharge switch between VO1 and VIN and the switch between VO2 and GND turn on and discharge the positive and the negative output voltages. After output voltages are discharged to zero, the switches turn off and the outputs stay in high impedance state. 7.6 Undervoltage lockout The undervoltage lockout function avoids improper operation of the device when the input voltage is not high enough. When the input voltage is below the UVLO threshold, the device is in shutdown mode. The hysteresis avoids unstable operation at input voltage levels close to the UVLO threshold. 7.7 Overtemperature protection An internal temperature sensor continuously monitors the IC junction temperature. If the temperature exceeds the specified value (see Table 5) the device stops operating. As soon as the temperature falls below the threshold (including hysteresis), normal operation is restored. 7.8 Short-circuit startup detection (SSD) During device soft-start on positive output, an internal comparator checks load condition to detect eventual panel damage. In such case soft-start is stopped and the device is parked in power-off. To reset the normal functionality (assuming that the anomalous load condition was removed), it is necessary to restart the converter by an enable transient. If no damage is detected during soft-start on the positive output, the startup procedure follows with negative output soft-start to reach, at the end, normal outputs functionality and voltages. 7.9 Overload protection (OLP) Output current is internally limited. An overload condition, as a short-circuit between the two outputs or between each output and GND, produces the device power-off. To reset normal functionality (assuming that the short condition was removed), it is necessary to restart the converter by an enable transient. 7.10 Short-circuit protection (SCP) When short-circuit occurs, the device is able to detect the voltage difference between VIN and VOUT. Overshoots are limited, decreasing the inductor current. After that, the output |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |